RMON Commands
show rmon alarm
SPS208G/SPS224G4/SPS2024 Command Line Interface Reference Guide
Field
Description
Sample Type
The method of sampling the variable and
calculating the value compared against the
thresholds. If the value is absolute, the value of the
variable is compared directly with the thresholds
at the end of the sampling interval. If the value is
delta, the value of the variable at the last sample is
subtracted from the current value, and the
difference compared with the thresholds.
Startup Alarm
The alarm that may be sent when this entry is first
set. If the first sample is greater than or equal to
the rising threshold, and startup alarm is equal to
rising or rising and falling, then a single rising alarm
is generated. If the first sample is less than or
equal to the falling threshold, and startup alarm is
equal falling or rising and falling, then a single
falling alarm is generated.
Rising Threshold
A sampled statistic threshold. When the current
sampled value is greater than or equal to this
threshold, and the value at the last sampling
interval is less than this threshold, a single event is
generated.
Falling Threshold
A sampled statistic threshold. When the current
sampled value is less than or equal to this
threshold, and the value at the last sampling
interval is greater than this threshold, a single
event is generated.
Rising Event
The event index used when a rising threshold is
crossed.
Falling Event
The event index used when a falling threshold is
crossed.
Owner
The entity that configured this entry.