Opening the Case

The enclosure is not designed to be opened.

Mounting Information

Mounting is achieved using the 4 X 5 mm holes on a 43 mm square. The ball joint bracket can be disconnected
from the display enclosure to enable mounting of the circular base to the required surface. Undo and remove the
two M4 bolts that clamp the base to the ball joint. The ball joint and display enclosure can now be removed from
the base by firmly pulling apart. It is advised that the lower cover of the display enclosure (to which the ball joint
is mounted) is firmly supported when pulling apart the ball joint mounting.
Once separated the base can be fixed to the desired surface.
To re-assemble firmly pop the ball joint and display enclosure back into the base mount and refit and tighten the
pair of M4 clamp bolts once the display has been positioned as required.

Antenna Position

The enclosure is fitted with a T24-ANTA antenna which is mounted in the top end of the enclosure.

Environmental Protection

The enclosure is sealed to IP67.