Battery Type
Usable Capacity
Sensor mA from xV Excitation
Usage Per 24 Hour Period
Mantracourt Electronics Limited
This is not a parameter of the module but information used by the battery life
guide. You can choose from some pre-set batteries or choose custom to allow
you to select your own battery capacity. See below. This will also offer to change
the Battery Low Level if the level suitable for the chosen battery is not the level
currently set.
This is not a parameter of the module but information used by the battery life
guide. This is the capacity of the battery in amp hours and has a profound effect
on battery life calculations. This capacity needs to be calculated from battery
manufacturer's data sheets to take into account that you can only use batteries
down to 2.1 volts so in the case of twin AA cells this would be 1.05 volts.
Generally the usable capacity will not be as high as that advertised by the
battery manufacturer. Temperature and internal resistance of the battery are not
taken into account in the guide.
This is the current drawn by any sensor attached to the user selectable
excitation on board power supply.
Enter the number of hours per 24 hour period that the module will be turned on
and transmitting.