Output Trigger Data Tag
Switch Mode
Remote data Tags and Timeouts
Data Tag
Timeout
Format
Mantracourt Electronics Limited
Enter the Data Tag which, on arrival, will trigger a serial output (i.e. print). Note
that Min Interval setting on the Output Settings page may stop this from
working at the rate at which the data arrives.
Version 02.00 firmware allows the user to enter zero here to cause the output to
automatically occur at 3Hz.
Action to perform when switch contacts on J5 are closed. Click to select either:
Print – Triggers an output from the serial port. Note that Min Interval setting
on the Output Settings page may stop this from working at the rate the contact
closes.
Gross/Zero – Toggles the measurement mode between gross and net. When
switching to net the net value is zeroed (tared). This will affect the value of the
<N> token which is the net value of all summed inputs.
Enter the Data Tag (in hexadecimal) to supply data to this input.
You can click the 'P' button to retrieve the Data Tag of a
module by pairing to it which is usually initiated by power
cycling the module.
Clicking the 'X' button zeroes the entered Data Tag.
Enter the timeout in milliseconds for this input. If a new Data Provider packet
does not arrive within this time and reference to this input value (via token
<V1> for example) will result in an output of -------. This also applies to a gross
or net reading derived from this input.
Describe the format that this value is to take when output. You specify integer
digits and decimal places by entering a format consisting of zeroes and decimal
points. i.e. 00.000
The integer value of data takes precedence over your defined
format so if you defined a format of 0.0 and data of value
100.8265 arrived it would be represented as 100.8
Examples
Format
0.0
0.0
00.000
00.000
0000.00
Resolution
It is possible to set the resolution (the smallest unit of change) of the output
results by including the numeric value in the format. i.e.
00.005 would only represent the value in steps of 00.005
Value
1.2
100.8
6.1234
123.4567
12.0
248
Representation
1.2
100.8
06.123
123.456
0012.00