Inputs (T24 Transmitters)

Here you can set timeouts and specify transmitters and also choose the interval between deliveries of data to the
cloud platform.
Items you can change:
Transmitter Timeout
Cloud Delivery Interval
Auto Fill Mode
Data Tag
Mantracourt Electronics Limited
Enter the maximum time to wait for data from a transmitter before indicating
that the transmitter has timed out by sending the new status to the cloud
platform and indicating errors on the LEDs.
Choose the interval between sending the transmitter data to the cloud platform.
When this mode is turned on the gateway will automatically search for new
transmitters and add them to the transmitter list for the first minute after being
powered up. This mode is useful if you intend to add more transmitters to a
site in the future without having to reconfigure the gateway.
The search for new modules is also initiated (for a minute) when you change
this setting from Off to On.
Use the tabs to access blocks of transmitters to access their data. Only the Data
Tags may be filled automatically when Auto Fill Mode is active.
Enter the 4 character hexadecimal Data Tag of the required transmitter. This
Data Tag will be used as the Variable name that is created on the SensorSpace
cloud platform in this device.
397
T24 Telemetry User Manual