On transition Only
Min Interval
Mantracourt Electronics Limited
Here you can decide whether the reports are sent all the time the trigger result
is true or only on a change of the result.
i.e. if the trigger is a low battery and the transition setting is NO then the report
will be sent at every Min Interval (Assuming not in low power mode) while the
battery is low.
If the transition setting is YES then the report will be sent once the battery
becomes low and again when it is no longer low. The min interval still applies.
This is the minimum interval in minutes between deliveries of the report. The
minimum number you can enter is 1.
Unlike the data log and CSV send intervals these intervals are not tied to
absolute time but are timed from the last sending of the report.
Also bear in mind that in Low Power or Ultra Low Power modes reports could
not be delivered more regularly than the Log Interval or the CSV Delivery
Interval respectively.