Digital IO

Here you can choose how to work with digital inputs and outputs..
Items you can change:
Digital Inputs
Mantracourt Electronics Limited
The state of the two digital inputs can be optionally delivered to SensorSpace
and the way the state is delivered can also be defined.
When the Digital Inputs are not Disabled then the variables DI1 and DI2 will be
delivered to SensorSpace where a value of 0 indicated input is inactive and a
value of 1 indicates it is active.
The options are:
Disabled – The variables are not delivered to SensorSpace.
Normal – The state of the digital inputs at the time of the normal scheduled
delivery to SensorSpace will be delivered as DI1 and DI2.
Latched – If a digital input has been activated at least once since the last
delivery then the state of the digital input will be delivered as active.
Real-time – The state of the digital inputs will be delivered to SensorSpace in
real-time as they change state. Do not expect that the gateway will be able to
track input changes faster than once per second.