Input Settings

Here you can set the action to take when the switch contacts are closed, set the Data Tag that will trigger an
output and also set the Data Tags of the data used as the inputs along with how the data is formatted.
Items you can change:
Waker Duration
Switch Mode
Output Trigger Data Tag
Mantracourt Electronics Limited
Entering a waker time in milliseconds will cause this module to wake transmitter
modules on the same radio channel and group key when it is turned on.
The external button/switch option may be made available on
future releases of the T24-PR1
Click to select either:
Print – Triggers an output from the serial port. Note that Min Interval setting
on the Output Settings page may stop this from working at the rate the contact
closes.
Gross/Zero – Toggles the measurement mode between gross and net. When
switching to net the net value is zeroed (tared). This will affect the value of the
<N> token which is the net value of all summed inputs.
Enter the Data Tag which, on arrival, will trigger an output (i.e. print). Note that
Min Interval setting on the Output Settings page may stop this from working
at the rate at which the data arrives.
This is usually set to the Data Tag of one of the inputs.