Schedules Tab
This tab sets the intervals at which data is collected and at which the CSV data is transmitted. This has an effect on
battery life as in Low and Ultra Low Power modes the Log Interval determines how often the module wakes from
a very low power sleep mode. See Battery Life section
Items you can change:
Schedules Tab
Log Interval
Every Hr Min
From Hr Min
Log Send Interval
Mantracourt Electronics Limited
This is the interval that the values from the transmitter modules are recorded as a
new row in the CSV data.
Specify the hours and minutes between the logs. Although this allows a minimum
of 1 minute intervals that will not be achievable in any of the low power modes as
it takes time to wake and connect to the GPRS network.
The above interval is not just arbitrarily calculated from the time the module is
switched on but is synchronised to real time. Here you can specify the time from
midnight to synchronise the interval from. i.e. you can set an interval of 8Hr 0Min
synchronised to 8Hr 0Min so the logs will take place at 8am, 4pm and 12pm.
This is the interval that the CSV data is transmitted to the specified destinations.