Connections

Power

You will need to connect power and serial to the T24-SO for it to operate. Only power is required on J4 to enable
configuration using a base station and the appropriate toolkit software.

Serial Settings

The serial output is set at 8 data bits, 1 stop bit and no parity. The baud rate can be selected as can RS232 or
RS485 operation.

SW1 Settings

Switch positions 1 to 4 are not used and can be in any position.
Switch positions 5 to 7 control the baud rate for the serial interface.
5
6
Baud rate
NA
Off
Off
9600
On
Off
19200
Off
On
38400
On
On
57600
Off
Off
115200
On
Off
230400
Off
On
460800
On
On
This switch position selects whether the serial interface is RS232 or RS485.
8
232/485
RS232
Off
RS485
On
Mantracourt Electronics Limited
2 TX
5
1
3 RX
5 GND
9
6
8 CTS
7
Off
Off
Off
Off
On
On
On
On