Display Format Advanced Settings
Here you can adjust the display update rate and also scale the displayed data. This may be used, for example, to
convert the data from a T24-SA calibrated in kg so that the handheld display shows lb.
Items you can change:
Display Update Rate
Custom Display Scaling
Mantracourt Electronics Limited
Enter the interval in milliseconds between display updates. The default is 300
milliseconds. i.e. 3 updates per second.
This can be used to change the displayed value to a different unit or to otherwise
scale it. You simply enter the original and required values at a low and high point.
Example: If a T24-SA was supplying data in kg and you wanted to show tonnes.
You would keep both the low points at zero. Enter At High Input Value of 1000
and Display Should Read Value of 1.
186
T24 Telemetry User Manual