Adv
nced Settings
a
You should not normally need to change these settings.
Items you can change:
Sleep Delay
Data Tag
Startup Time
LED Mirror to Digital
Output
Transmit power
Mantracourt Electronics Limited
Here you can enter a delay in seconds after which the transmitter module will return to
deep sleep if no Keep Awake message is heard from a receiver module or software.
The default is 60 seconds.
The data transmitted by the transmitter module is marked with a Data Tag which is a 2
byte hexadecimal code. By default this is set to the last 2 bytes of the module ID (or to
put it another way, the last 4 characters of the module ID).
If by some chance you had two transmitter modules that would be working on the
same channel and had the same last 4 characters in their ID (1 in 65,535 chances) you
may want to change the data Tag of one of the modules.
Some transmitter modules power a sensor from their excitation voltage. When
coupled to a sensor with a slow startup time this setting is used to delay the
measurement after wakeup from sleep between readings. This gives the sensor time to
settle at the expense of battery life.
Only available in Frequency, RPM and Interval Output Type modes and where Low
Power Mode is activated. Also note that the startup time should be less than the
Transmit Interval.
When set to Yes each time the LED is active the digital output is active.
This can be useful if the module is to be encapsulated or enclosed and enables a
second LED to be externally mounted. This is very useful when using a T24-HR
roaming handheld as the transmitter module LED will activate while the handheld is in
communications with the module.
Set the transmit power level from 0 – 100%.
Default is 100%