In Maximum
Input value
Output
Smoothing
Current Selected Output
Mantracourt Electronics Limited
Enter the input value that should result in the maximum output. The maximum
output depends on the Current Selected Output which is determined by the SW2
DIP switch settings.
Range
Maximum
Output
0-10 V
+/-10 V
0-5 V
+/-5 V
0-20 mA Sink
0-20 mA Source
4-20 mA Sink
4-20 mA Source
This shows the currently supplied value to the T24-AO1. An active transmitter
module must be in place to view this value.
Click Format to select a display format.
Click here to select whether to apply smoothing to the output.
The analogue output is updated at a rate of 2KHz.
When no smoothing is applied the output changes as soon as new data arrives
from the transmitter module.
When smoothing is active the output is ramped between the last input value and
the current input value at a rate of 2KHz. This has the effect of delaying the
output (latency) by the interval between values being delivered to the input. i.e.
The T24-AO1 must receive an input value then start to ramp up to it from the
previous input value.
Example: with a transmitter module delivering data at 3Hz the T24-AO1 output
would have a latency of 333ms when smoothing is active.
This option will have no effect when the input module is a
T24-SAf 2KHz fast transmitter.
This shows the currently selected output range as set by the SW2 DIP switches.
Some of the DIP switches are used to indicate to the
module the selected range and others are used to route
circuitry so although this display may indicate the selected
range that does not mean that all switches are in the correct
position for the range to work correctly. Always check the
SW2 DIP switch table for the correct settings.