T24-Acm-Pa; Power; Sensor - Mantracourt T24 User Manual

Hide thumbs Also See for T24:
Table of Contents

Advertisement

T24-ACM-PA

Power

Power can be supplied by fitting two D cell alkaline 1.5 V batteries or the module can be supplied from an
external 5 Vdc to 18 Vdc source.
In both cases you need to fit the JP1 power jumper to supply power to the transmitter module.
When powered from the external DC source the LED will illuminate.
For battery information please refer to

Sensor

The pulse input is connected to the module via a 2 part screw terminal block.
Screw Terminal
Function
1
+Excitation
2
Input A
3
Input B
4
- Excitation (GND)
5
Shield
7
Reset Count
See
T24-PAe, T24-PAi
section above for wiring options.
Mantracourt Electronics Limited
Power J umper J P1
1
2
3
4
5
2 X D Cell Batteries
6
7
0V
+Supply
LED