Mantracourt T24 User Manual page 146

Hide thumbs Also See for T24:
Table of Contents

Advertisement

Pulses per Revolution
Excitation Type
Debounce Filter
Input Resistor
Edge Type
Minimum RPM/Frequency
Advanced Button
Mantracourt Electronics Limited
Specify the number of pulses per revolution. This parameter only affects the
RPM output value.
The excitation voltage can be selected to power external sensors if required. The
choices are Off, 3V, 5V or 12V. The module will calculate when it can save power
by turning off the excitation based on the Minimum Frequency. If, when
powering up the sensor, it requires some time to stabilise, the Startup Time in
the Advanced Tab can be used.
Enter a time in milliseconds, any pulse that is received within this time of a
previous pulse will be ignored, this is useful when dealing with noisy inputs such
as relays which may inadvertently produce more than one pulse per event.
Select whether the inputs are pulled up or pulled down with internal 56K
resistors.
Define which edge of an input pulse should be counted as the input trigger.
By entering the minimum frequency or RPM measurement required, the module
can calculate the most effective form of power saving to apply.
Not available in Counter, Quadrature and Digital State output modes.
Click to show the advanced page described below.
145
T24 Telemetry User Manual