Zero Settings

Use this page to set a system zero.
Parameters:
Perform System Zero
Remove System Zero
Advanced Button
Mantracourt Electronics Limited
Clicking this will store the current values on all inputs and subtract the value
from all subsequent outputs thus rendering the current input as zero.
Example: A 4 input weigh platform will have calibrated transmitter modules but
when the actual platform structure is in place each module has a weight value
thus the gross value is 50kg.
By performing a system zero (with all inputs operational) this is zeroed away so
next time the T24-LD1 is powered on the same input will yield a zero result.
This does not affect the data transmitted from the
transmitter modules.
Clicking this will remove all system zeros and restore all outputs to normal.
Show the Zero Settings Advanced page.