Interrupt control register (Note 1)
www.DataSheet4U.com
b7
b7
Figure 2.15.2. Interrupt control registers
Rev.2.00 Oct 16, 2006
REJ09B0340-0200
Symbol
KUPIC
S2RIC
S13BCNIC
TA1IC
EP0IC
TA2IC
S0RIC
ADIC
DM0IC
S3TIC
DM1IC
b6
b5
b4
b3
b2
b1
b0
S2TIC
DM2IC
Bit symbol
ILVL0
ILVL1
ILVL2
IR
Nothing is assigned. Write "0" when writing to these bits.
The contents are indeterminate if read.
b6
b5
b4
b3
b2
b1
b0
0
Bit symbol
ILVL0
ILVL1
ILVL2
IR
POL
Reserved bit
Nothing is assigned. Write "0" when writing to these bits.
The contents are indeterminate if read.
Note 1: To rewrite the interrupt control register, do so at a point that dose not generate the
interrupt request for that register. For details, see the precautions for interrupts.
Note 2: This bit can only be reset (=0), but cannot be set (=1).
Note 3: For S1RIC ( 0048
page 268 of 354
Address
When reset
0041
XXXXX000
16
2
0042
XXXXX000
16
2
0043
XXXXX000
16
2
0045
XXXXX000
16
2
0046
XXXXX000
16
2
0047
XXXXX000
16
2
004A
XXXXX000
16
2
004B
XXXXX000
16
2
004C
XXXXX000
16
2
004D
XXXXX000
16
2
004E
XXXXX000
16
2
004F
XXXXX000
16
2
0050
XXXXX000
16
2
Bit name
Interrupt priority level
b2 b1 b0
select bit
0 0 0 : Level 0 (interrupt disabled)
0 0 1 : Level 1
0 1 0 : Level 2
0 1 1 : Level 3
1 0 0 : Level 4
1 0 1 : Level 5
1 1 0 : Level 6
1 1 1: Level 7
Interrupt request bit
0 : Interrupt not requested
1 : Interrupt requested
Address
Symbol
0044
INT1IC
16
0048
16
S1RIC
0049
16
S02BCNIC
005E
16
INT2IC
005F
16
INT0IC
Bit name
Interrupt priority level
b2 b1 b0
0 0 0 : Level 0 (interrupt disabled)
select bit
0 0 1 : Level 1
0 1 0 : Level 2
0 1 1 : Level 3
1 0 0 : Level 4
1 0 1 : Level 5
1 1 0 : Level 6
1 1 1: Level 7
0 : Interrupt not requested
Interrupt request bit
1 : Interrupt requested
Polarity select bit
0 : Selects falling edge
1 : Selects rising edge
Always set to "0"
) and S02BCNIC ( 0049
16
2. Multiple Interrupts
Symbol
Address
When reset
S1TIC
0051
XXXXX000
16
DM3IC
0052
XXXXX000
16
S0TIC
0053
XXXXX000
16
TA0IC
0054
XXXXX000
16
S3RIC
0055
XXXXX000
16
SUSPIC
0056
XXXXX000
16
TA3IC
0057
XXXXX000
16
RSMIC
0058
XXXXX000
16
TA4IC
0059
XXXXX000
16
RSTIC
005A
XXXXX000
16
SOFIC
005B
XXXXX000
16
VBSIC
005C
XXXXX000
16
USBFIC
005D
XXXXX000
16
Function
R
(Note 2)
When reset
XX00X000
2
XX00X000
2
XX00X000
2
XX00X000
2
XX00X000
2
Function
W
R
(Note 2)
(Note 3)
), "0" should always be written.
16
2
2
2
2
2
2
2
2
2
2
2
2
2
W

Advertisement

Table of Contents
loading

Table of Contents