Logic Analyzer Reference
The Chart Menu
Min and Max scaling fields
When State is selected for the X axis, the minimum and maximum
values can range from -8192 to +8192 for the 1660E-series logic
analyzers, depending on the trace point location. For the 1670E-series
logic analyzers, the values can range from -1 M to +1 M.
When Label is selected for either axis, the minimum and maximum
values range from 00000000 hex to FFFFFFFF hex regardless of the
axis, because labels are restricted to 32 bits.
Markers/Range field
The Marker/Range field is a toggle field. If the field is set to Range, X
and Y range fields become available to set the chart minimum and
maximum range points. If the field is set to Markers, a marker selection
menu appears with marker choices available with the present analyzer
configuration.
In a state analyzer with Count Off in the Trigger menu, only Pattern
markers are available. With Count Time on, Time markers and
Statistics markers become available. With Count States on, States
markers are available. The markers function just like those of the
Waveform and Listing displays.
352