To Build An Initialization Sequence - Agilent Technologies HP 1660E Series User Manual

Logic analyzers
Table of Contents

Advertisement

Using the Pattern Generator
Building Test Vectors and Macros

To build an initialization sequence

Use the INIT SEQUENCE to place the system under test into a known
initialization state. Default start and end program vectors are marked
INIT SEQUENCE START and INIT SEQUENCE END. During a
repetitive run, the initialization sequence is only executed the first time
the program is run. The main sequence then loops repetitively.
1 From the Sequence menu, use the knob to highlight INIT
SEQUENCE START.
2 Select the Insert field once for each new line of vectors you want
inserted into the initialization sequence.
These new lines of vectors provide fields to place data into for each
label.
3 Select the data field, then type in a data value.
If you are adding data in many fields, use the Autoroll feature. Refer to
"To use Autoroll" later in this chapter.
158

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp 1660es seriesHp 1660ep series1670e series

Table of Contents