The Analyzer Format Menu; Pod Threshold Field - Agilent Technologies HP 1660E Series User Manual

Logic analyzers
Table of Contents

Advertisement

Logic Analyzer Reference

The Analyzer Format Menu

The Analyzer Format Menu

Pod threshold field

The pod threshold field is used to set a voltage level that the data must
reach before the analyzer recognizes and displays it as a change in logic
levels. Threshold levels apply to single pods, and cover both data and
clock channels.
TTL. When TTL is selected, the threshold level is +1.5 volts.
ECL. When ECL is selected, the threshold level is -1.3 volts.
User. When User is selected as the threshold level, the data signals
must reach a user selectable value. The range of this value is between -
6.0 volts to +6.0 volts in 50-mV increments.