F126
Input Terminal 16 (LI8) Function
Program Terminal Input Terminals
This parameter selects the functionality of the LI8 discrete input terminal.
In addition, this input terminal must be specified as Normally Open or
Normally Closed.
This setting assigns the function of the programmable LI8 terminal to one of
the user-selectable functions listed in
Note:
The Expansion IO Card Option 1 option board (P/N ETB003Z)
is required to use this terminal.
See the Expansion IO Card Option 1 instruction manual (P/N 58685) for
additional information on the function of this terminal.
Output Terminal 1 (OUT1) Function
Program Terminal Output Terminals
This parameter sets the functionality of the OUT1 (A & C) output terminals to
any of the possible functions that are listed in
The on and off delay times of the OUT1 terminals may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output terminals must be specified as Normally Open or
Normally Closed.
Output Terminal 2 (OUT2) Function
Program Terminal Output Terminals
This parameter sets the functionality of the OUT2 (A & C) output terminals to
any of the possible functions that are listed in
The on and off delay times of the OUT2 terminals may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output terminals must be specified as Normally Open or
Normally Closed.
Output Terminal 3 (FL) Function
Program Terminal Output Terminals
This parameter sets the functionality of the FL output terminals to any of the
possible functions that are listed in
The on and off delay times of the FL terminals may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output terminals must be specified as Normally Open or
Normally Closed.
86
Table 10 on pg.
182.
Table 11 on pg.
186.
Table 11 on pg.
186.
Table 11 on pg.
186.
Direct Access Number — F126
Parameter Type — Selection List
Factory Default — No Function is
Assigned
Changeable During Run — No
Direct Access Number — F130
Parameter Type — Selection List
Factory Default — LOW: Low Speed
Signal
Changeable During Run — No
Direct Access Number — F131
Parameter Type — Selection List
Factory Default — RCH: ACC/DEC
Completion
Changeable During Run — No
Direct Access Number — F132
Parameter Type — Selection List
Factory Default — Failure FL (All
Trips)
Changeable During Run — No
WX9 ASD Installation and Operation Manual