Regenerative Braking Torque Limit 2 Level
(250% = disabled)
Program Torque Manual Torque Limit Settings
This parameter is used to set the negative torque upper-limit for the 2 Motor
Profile when multiple motors are controlled by a single drive or when a single
motor is controlled by multiple profiles.
Power Running Torque Limit 3 Level (250% = disabled)
Program Torque Manual Torque Limit Settings
This parameter is used to set the positive torque upper-limit for the 3 Motor
Profile when multiple motors are controlled by a single drive or when a single
motor is controlled by multiple profiles.
Regenerative Braking Torque Limit 3 Level
(250% = disabled)
Program Torque Manual Torque Limit Settings
This parameter is used to set the negative torque upper-limit for the 3 Motor
Profile when multiple motors are controlled by a single drive or when a single
motor is controlled by multiple profiles.
Power Running Torque Limit 4 Level (250% = disabled)
Program Torque Manual Torque Limit Settings
This parameter is used to set the positive torque upper-limit for the 4 Motor
Profile when multiple motors are controlled by a single drive or when a single
motor is controlled by multiple profiles.
Regenerative Braking Torque Limit 4 Level
(250% = disabled)
Program Torque Manual Torque Limit Settings
This parameter is used to set the negative torque upper-limit for the 4 Motor
Profile when multiple motors are controlled by a single drive or when a single
motor is controlled by multiple profiles.
Torque Limit Mode
Program Torque Torque Limit Settings
Contact the TIC Customer Support Center for information on this parameter.
Settings:
0 — Power Running/Regenerative Torque Limit
1 — Positive/Negative Torque Limits
WX9 ASD Installation and Operation Manual
Direct Access Number — F445
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0
Units — %
Direct Access Number — F446
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0
Units — %
Direct Access Number — F447
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0
Units — %
Direct Access Number — F448
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0
Units — %
Direct Access Number — F449
Parameter Type — Numerical
Factory Default — 250.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0
Units — %
Direct Access Number — F450
Parameter Type — Selection List
Factory Default — Power Running /
Regenerative Torque
Limit
Changeable During Run — No
F450
145