F290
Preset Speed 11
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1011 and is
identified as Preset Speed 11. The binary number is applied to S1 – S4 of the
Control Terminal Strip to output the Preset Speed (see
information on this parameter).
Preset Speed 12
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1100 and is
identified as Preset Speed 12. The binary number is applied to S1 – S4 of the
Control Terminal Strip to output the Preset Speed (see
information on this parameter).
Preset Speed 13
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1101 and is
identified as Preset Speed 13. The binary number is applied to S1 – S4 of the
Control Terminal Strip to output the Preset Speed (see
information on this parameter).
Preset Speed 14
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1110 and is
identified as Preset Speed 14. The binary number is applied to S1 – S4 of the
Control Terminal Strip to output the Preset Speed (see
information on this parameter).
Preset Speed 15
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1111 and is
identified as Preset Speed 15. The binary number is applied to S1 – S4 of the
Control Terminal Strip to output the Preset Speed (see
information on this parameter).
WX9 ASD Installation and Operation Manual
Direct Access Number — F290
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
F018
for additional
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F291
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
F018
for additional
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F292
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
F018
for additional
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F293
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
F018
for additional
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F294
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
F018
for additional
Maximum — Upper-Limit Freq. (F012)
Units — Hz
F294
119