Toshiba WX9 ASD Installation & Operation Manual page 186

Table of Contents

Advertisement

F811
Point 1 Setting
Program Communications Communication Adjustments
When enabled at Frequency Point Selection (F810), this parameter is used to
allow the user to set the gain and bias of the speed control input to the drive
when the speed control signal is received via the source selected at Frequency
Point Selection (F810).
Gain and Bias Settings
When operating in the Speed Control mode and using one of the control
sources from Settings above, the settings that determine the gain and bias
properties of the input signal are:
Communications Point 1 Frequency (F812),
the communications input signal value that represents
Communications Point 1 Setting (F811),
Communications Point 2 Frequency (F814), and
the communications input signal value that represents
Communications Point 2 Setting (F813).
Once set, as the input signal value changes, the output frequency of the drive
will vary in accordance with the above settings.
This parameter sets the Communications Reference input value that represents
Communications Point 1 Setting. This value is entered as 0 to 100% of the
Communications Reference input value range.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Point 1 Frequency
Program Communications Communication Adjustments
This parameter is used to set the gain and bias of the Communications
Reference speed control input.
See Point 1 Setting
(F811)
This parameter sets Point 1 Frequency.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Point 2 Setting
Program Communications Communication Adjustments
This parameter is used to set the gain and bias of the Communications
Reference speed control input.
See Point 1 Setting
(F811)
This parameter sets the Communications Reference input value that represents
Point 2 Setting. This value is entered as 0 to 100% of the Communications
Reference input value range.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
174
for additional information on this setting.
for additional information on this setting.
Direct Access Number — F811
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 100.0
Units — %
Direct Access Number — F812
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Maximum Freq. (F011)
Units — Hz
Direct Access Number — F813
Parameter Type — Numerical
Factory Default — 100.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — 100.0
Units — %
WX9 ASD Installation and Operation Manual
F813

Advertisement

Table of Contents
loading