F630
Brake Answer Waiting Time
Program Protection Special Protection Parameters
This parameter is used in conjunction with the discrete input terminal setting
64 [System Consistent Sequence (BA: braking answer)] (see item 64 of
10 on pg. 182
for additional information on this feature).
After activating the discrete input terminal System Consistent Sequence (B:
braking release), the setting of this parameter defines a window of time in
which 1) a Braking Answer response must be received, or 2) the brake must
release.
Should this timer setting expire before the Braking Answer is returned or the
brake releases, a Brake Fault (E-11) is incurred. Otherwise, the brake releases
and normal motor operations resume.
Brake Release After Run Timer
Program Protection Special Protection Parameters
This parameter sets the time that the brake will hold after the Run command
criteria has been met.
Earth Fault Alarm Level
Program Special Earth Fault
This parameter sets the threshold level (%) that must be exceeded to meet the
Earth Fault Alarm activation criteria.
Earth Fault Alarm Time
Program Special Earth Fault
In the event that the Earth Fault Alarm activation criteria is met, a timer
begins to count down to zero. Upon reaching zero, the Earth Fault Alarm is
activated.
This parameter sets the start-time of the count-down timer.
Earth Fault Trip Level
Program Special Earth Fault
This parameter sets the threshold level (%) that must be exceeded to meet the
Earth Fault Trip activation criteria.
WX9 ASD Installation and Operation Manual
Direct Access Number — F630
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Table
Minimum — 0.00
Maximum — 10.00
Units — Seconds
Direct Access Number — F632
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — No
Minimum — 0.00
Maximum — 2.50
Units — Seconds
Direct Access Number — F640
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — No
Minimum — 0
Maximum — 100
Units — %
Direct Access Number — F641
Parameter Type — Numerical
Factory Default — 1.00
Changeable During Run — No
Minimum — 0.00
Maximum — 2.50
Units — Seconds
Direct Access Number — F642
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — No
Minimum — 0.00
Maximum — 100
Units — %
F642
163