F007
Type Reset
Reset
Program Utilities Type Reset
This feature assists the user when performing fault analysis or by allowing a
quick system setup change when required. Performing a Type Reset results in
one of the following user-selected post-reset configurations.
Settings:
0 — None
1 — 50 Hz Setting
2 — 60 Hz Setting
3 — Reset to Factory Settings
4 — Clear Past Trips
5 — Clear Run Timer
6 — Initialize Typeform
7 — Save User Settings
8 — Restore User Settings
9 — Reset EOI to Factory Settings
Note:
*User settings that are stored in the memory of the EOI are not
saved via the Save User Parameters selection. The unsaved
functions include the EOI Option Setups, (Utility Parameters
 Display Units, and (Monitor Setup ) Scrolling Monitor
Select.
Acceleration Time 1
Program Fundamental Acc/Dec 1 Settings
Program Special Acc/Dec (1 - 4) Settings
This parameter specifies the time in seconds for the drive to go from 0.0 Hz to
the Maximum Frequency (F011) for the Acceleration 1 Profile. The
Acceleration/Deceleration (Acc/Dec) pattern may be set using F502. The
minimum Acc/Dec time may be set using F508.
Note:
An acceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Automatic Acceleration/Deceleration and Stall settings may
lengthen the acceleration time.
Acceleration
The acceleration rate of a motor is determined by several factors: applied
power, applied load, and the physical properties of the motor (winding
parameters, motor size, etc.). The ASD will control the first of these factors:
input power. The settings of the ASD control the frequency and amplitude of
the applied voltage to the motor.
Under most operating conditions, as the output frequency of the drive goes up
so does the output voltage (linear acceleration). The ASD has the ability to
modify the relationship between frequency and voltage automatically to
produce smoother operation or increased (starting) torque.
72
Direct Access Number — F007
Parameter Type — Selection List
Factory Default — None
Changeable During Run — No
Direct Access Number — F009
Parameter Type — Numerical
Factory Default — (ASD-Dependent)
Changeable During Run — Yes
Minimum —
Maximum — 6000
Units — Seconds
WX9 ASD Installation and Operation Manual