F412
Motor Rated Capacity (nameplate)
Program Motor Vector Motor Model
This parameter identifies the wattage rating of the motor.
Motor Type
Program Motor Vector Motor Model
This parameter identifies the type of motor being used.
Settings:
0 — Toshiba EQP III TEFC
1 — Toshiba EQP III ODP
2 — Toshiba EPACT TEFC
3 — Toshiba EPACT ODP
4 — Other Motor
Autotune of Motor Constant 3
Program Motor Vector Motor Model
This parameter Enables/Disables tuning of Motor Constant 3 during an
Autotune.
Settings:
0 — Prohibited
1 — Valid for Sensorless Vector
2 — Valid for Vector with PG
Torque Command Selection
Program Torque Torque Control
When operating in the Torque Control mode, this parameter allows the user to
select the source of the torque command signal.
Settings:
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — CN8 Option
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Torque Command Filter
Program Torque Torque Control
This parameter reduces the motor vibration caused by large-inertia loads. A
small value will have a great effect while an increased value will have a lesser
effect.
140
Direct Access Number — F412
Parameter Type — Numerical
Factory Default — (ASD-Dependent)
Changeable During Run — No
Minimum — 0.10
Maximum — (ASD-Dependent)
Units — kW
Direct Access Number — F413
Parameter Type — Selection List
Factory Default — Toshiba EQP III
TEFC
Changeable During Run — No
Direct Access Number — F414
Parameter Type — Selection List
Factory Default — Valid for Sensorless
Vector
Changeable During Run — No
Direct Access Number — F420
Parameter Type — Selection List
Factory Default — RX
Changeable During Run — Yes
Direct Access Number — F421
Parameter Type — Numerical
Factory Default — 200.0
Changeable During Run — Yes
Minimum — 10.0
Maximum — 200.0
WX9 ASD Installation and Operation Manual