Toshiba WX9 ASD Installation & Operation Manual page 145

Table of Contents

Advertisement

F367
Number of PG Input Pulses
Program Feedback PG Settings
This parameter is used to set the end-of-travel range when using an encoder on
a motor-driven positioning system (e.g., hoist/crane, etc.).
Note:
The PG Vector Feedback Board option is required to use this
feature.
Selection of Number of PG Input Phases
Program Feedback PG Settings
This parameter determines the type of information that is supplied by the phase
encoder.
Note:
The PG Vector Feedback Board option is required to use this
feature.
Settings:
1 — Single Phase
2 — Two Phase
PG Disconnection Detection
Program Feedback PG Settings
This parameter Enables/Disables the system's monitoring of the PG connection
status when using encoders with line driver outputs.
Note:
The PG Vector Feedback Board option is required to use this
feature.
Settings:
0 — Disabled
1 — Enabled
Electronic Gear Setting (pulses/rotations)
Program Feedback PG Settings
This parameter sets the number of pulses per revolution when using a shaft-
mounted encoder and the PG Option Board for closed loop speed control.
WX9 ASD Installation and Operation Manual
Direct Access Number — F367
Parameter Type — Numerical
Factory Default — 500
Changeable During Run — No
Minimum — 1
Maximum — 9999
Units — Pulse Count
Direct Access Number — F368
Parameter Type — Selection List
Factory Default — Two Phase
Changeable During Run — No
Direct Access Number — F369
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Direct Access Number — F370
Parameter Type — Numerical
Factory Default — 1000
Changeable During Run — Yes
Minimum — 100
Maximum — 4000
F370
133

Advertisement

Table of Contents
loading

Table of Contents