6.4 Dip Switch

Set the dipswitches to select the operating modes as shown in Table 6.4, 6.5 and 6.6.
No.
1
Data Length
2
Monitor Cooling water and N2
3
Buzzer
4
Operation switched to Remote
5
External start/stop signal
6
-----
7
Dilution N2 mode
8
BP operation in Remote
No.
1
-----
2
-----
3
-----
4
Pump N2 valve control*
5
-----
6
Remote Interface (IF) *
7
Phase error monitoring
8
LCD screen initialize
* Optional
No.
1
Outputs the pump N2 warning.
2
3
Outputs backpress. warning. *
4
5
6
Valve ON/OFF control *
7
The output of a valve state *
8
* Optional
DIP SW-A. No.1
PM10U
Table 6.4 Dip Switch-A Settings
Mode
According to signal
Alternate (Level)
Standard mode
Automatic operation
Table 6.5 Dip Switch-B Settings
Mode
Exclusive special IF
Carry out initialize
Table 6.6 Dip Switch-C Settings
Mode
Normal Open
-------
Normal Open
-------
-------
-------
In case of observing pump running status with RS232C
communication port, Data Length can be selected out of
7bits and 8bits.
Off
7bits
Always
Only during operation
Not used
Automatically stop
Momentary (Pulse)
-----
Dilution N2-0 mode
External signal input
Off
-----
-----
-----
No
-----
No use / standard IF
Standard
During starting only
Do not initialize
Off
Normal Close
-------
Normal Close
-------
-------
Not used
Not used
-------
P.41
On
Factory
setting
8bits
ON
OFF
Use
ON
OFF
OFF
-----
-----
OFF
OFF
On
Factory
setting
-----
-----
-----
-----
-----
-----
Yes
OFF
-----
-----
ON
OFF
OFF
On
Default
Off
-------
-------
Off
-------
-------
-------
-------
Used
Off
Used
Off
-------
-------
EBARA
CORPORATION