Download Print this page

Installation; Movement And Fixation; Location; Caster And Adjustment Foot - EBARA ESA200W Instruction Manual

Multi-stage dry vacuum pump

Advertisement

P.12

4. Installation

Be sure to take the following cautions and instructions into account when
installing the pump.

4.1 Movement and Fixation

4.1.1 Location

This pump is designed for indoor installation. To install the pump, select a place
with little exposure to dust and humidity and not subject to dew condensation.
Also allow for sufficient space to ensure easy pump installation and disassembly
for maintenance.
In case of installing interface box to the pump, the distance between pump
and interface box shall be 3m or less.
CAUTION
CAUTION

4.1.2 Caster and adjustment foot

Four integral mobile support units consisting of a caster and a height-adjustment
foot each are provided underneath the pump base. To move the pump, raise the
four adjustment feet by turning the holding nuts in the counterclockwise direction.
PM10U
Install pump in a location at an ambient not exceeding 30°C.
Particular caution is required when the pump is operated in
an enclosed room.
A gap of at least 50mm should be left open for ventilation
between the pump cover and the adjacent equipment.
Caster
Fig. 4.1 Caster
Adjuster
(Vibroisolating rubber)
Approx 15mm
EBARA
CORPORATION

Advertisement