4.3.4 Additional Emergency Off (EMO) input

In addition to the emergency off button, which stops the pump and interrupts all
primary voltage outside the main control panel, pump has a connector for an
"emergency" signal input. The user may place this connector in any external
interlock circuit (e.g. scrubber failure, gas leak detection, EMO "daisy chain").
Any break in this external circuit will shut down the pump.
Additional EMO input connector "EXT. IO" is located on front panel. Refer to
outline drawing shown in section 3.5. (Near signal connector port.)
CAUTION Dummy plug should be connected on "EXT.IO" receptacle
Plug
Pin
Suitable wire size
Required capacity of user side facility
Signal input at NORMAL condition
Signal input at EMERGENCY condition
PM10U
during operation. Pump does not run without dummy plug,
because it means same as EMO signal was input.
Table 4.8 Additional EMO input Specification
HIROSE DF1B-2EP-2.5RC
HIROSE DF1-PD2428SCB
UL1007 AWG#24
DC12V 20mA added by pump side.
NO voltage required from outside
Close between two pins of the plug
Open between two pins of the plug