6.3 Setting the operational mode

This section describes how to set the operational mode. In the normal state, the
LCD controller displays pump status. To display the operational mode setting
screen, press the key "PRG." for three seconds or longer. Pressing the key for
one second or longer again returns to the pump status display screen. Table 6.3
below shows indications and the details of the operational mode setting.
Item
Setting the pump operation
control mode
Setting the DIP switch
Setting the pump running
mode
Setting the rotational speed
in the RATED mode
Setting the rotational speed
in the S. ENERGY mode
Setting the WARNING value
for the back pressure
(option)
Keys work as below for the setting screen.
START
STOP
RESET
BZ.OFF
ENTER
See Fig. 6.3 for how to set the operational modes.
PM10U
Table 6.3
Operational mode setting screen
Indication
SET
CONTROL MODE?
SET
DIP SW?
SET
RUNNING MODE?
SET
RATED SPEED?
SET
S.ENERGY SPEED?
SET ALARM SP
BACK PRES.?
:
Valid
:
Stops the pump.
:
Resets WARNING and /or ALARM.
:
Switches the DIP switch No.
:
Sets the DIP switch to ON. Switches the display of the operational
mode setting screen.
:
Sets the DIP switch to OFF.
operational mode setting screen.
:
Determines the selected setting.
Description
Switches the control modes:
local ,remote, communication.
Performs the DIP switch settings
(see 6.4).
Switches the running modes:
NORMAL and S. ENERGY.
Sets the pump rotational speed
in the RATED mode.
Sets the pump rotational speed
in the S. ENERGY mode.
Sets the WARNING value for
the backpressure.
Switches the display of the