Goodrive3000 series medium voltage VFD
Function
Name
code
P10.36
PLC restart
Multi-step time
P10.37
unit
P11 group––Protective parameters
Phase loss
P11.00
protection
Instantaneous
power loss
P11.01
frequency
decreasing
Frequency
decreasing
P11.02
velocity of
instantaneous
power loss
Overvoltage
P11.03
speed loss
protection
Voltage
P11.04
protection of
overvoltage stall
Current limit
P11.05
action
Description
0: Restart from the first step
1: Continue to run from the stop
frequency
0: Second
1: Minute
0x00–0x11
LED ones:
0: Disable input phase loss protection
1: Enable input phase loss protection
LED tens:
0: Disable output phase loss protection
1: Enable output phase loss protection
0: Disabled
1: Enabled
0.00Hz/s–P00.03Hz/s (Max. frequency) 0.00Hz–P00.03 10.00Hz/s
0: Disabled
1: Enabled
120–150% (standard bus voltage)
Ones: current limit
0: Invalid
1: Valid
Tens: overload alarm of hardware
current limit (for factory commissioning)
0: Valid
1: Invalid
-228-
Goodrive3000 inverter
Setting range
Default
0–1
0
0–1
0
00–11
11
0–1
0
0–1
1
120–150%
130%
00–11
01
Modify
◎
◎
○
○
○
○
○
◎