Goodrive3000 series medium voltage VFD
Function
Name
code
Keypad setting
P04.28
voltage
Voltage
P04.29
increasing time
Voltage
P04.30
decreasing time
Max. output
P04.31
voltage
Min output
P04.32
voltage
P04.33
Reserved
P04.34
Reserved
P04.35
Reserved
P05 group––Input terminals
P05.00
HDI input type
S1 terminal
P05.01
function
S2 terminal
P05.02
function
S3 terminal
P05.03
function
S4 terminal
P05.04
function
P05.05
S5 terminal
Description
5: Multi-step setting (Determined by the
multi-step speed parameter of P10)
6: PID setting
7: MODBUS communication setting
8: PROFIBUS/CANopen
communication setting
9: Ethernet communication setting
10: Reserved
0.0%–100.0% (Motor rated voltage)
0.0–3600.0s
0.0–3600.0s
P04.32–100.0% (Motor rated voltage)
0.0%–P04.31 (Motor rated voltage)
0: HDI is pulse input.
1: HDI is switch input.
0: No function
1: Forward rotation operation
2: Reverse rotation operation
3: 3-wire control operation
4: Forward rotation jogging
5: Reverse rotation jogging
6: Coast to stop
7: Fault reset
8: Operation pause
-202-
Goodrive3000 inverter
Setting range
Default
0.0–100.0
100.0%
0.0–3600.0
5.0s
0.0–3600.0
5.0s
0.0–100.0
100.0%
0.0–100.0
0.0%
0–1
0
0–63
1
0–63
4
0–63
7
0–63
0
0–63
0