Parameter Description
K-15 Readout: Actual Set-up
Range:
0
[0 - 255]
*
3.1.3 K-2# Keypad Display
Define the variables displayed in the keypad.
[0]
None
No display value selected
*
[537]
Display Text 1
Enables an individual text string to be
written, for display in the keypad or to
be read via serial communication.
[538]
Display Text 2
Enables an individual text string to be
written, for display in the keypad or to
be read via serial communication.
[539]
Display Text 3
Enables an individual text string to be
written, for display in the keypad or to
be read via serial communication.
[589]
Date and Time
Displays the current date and time.
Readout
[953]
Profibus
Displays Profibus communication
Warning Word
warnings.
[2205] Readout
View the number of CAN control
Transmit Error
transmission errors since the last power-
Counter
up.
[2206] Readout
View the number of CAN control receipt
Receive Error
errors since the last power-up.
Counter
[2207] Readout Bus
View the number of Bus Off events
Off
since the last power-up.
Counter
[2213] Warning
View a DeviceNet-specific warning word.
Parameter
One separate bit is assigned to every
warning.
[1501] Running Hours
View the number of running hours of
the motor.
[1502] kWh Counter
View the mains power consumption in
kWh.
[1200] Control Word
View the Control Word sent from the
frequency converter via the serial
communication port in hex code.
[1201] Reference [Unit] Total reference (sum of digital/analog/
preset/bus/freeze ref./catch up and
slow-down) in selected unit.
[1202] Reference [%]
Total reference (sum of digital/analog/
preset/bus/freeze ref./catch up and
slow-down) in percent.
[1203] Status Word
Present status word
[1205] Main Actual
View the two-byte word sent with the
Value [%]
Status word to the bus Master reporting
the Main Actual Value.
[1209] Custom
View the user-defined readouts as
Readout
defined in parameter K-30 Unit for
Custom Readout, parameter K-31 Min
Value of Custom Readout and
DET-620D
AF-600 FP™ Programming Guide
Function:
03/2016 All rights reserved.
parameter K-32 Max Value of Custom
Readout.
[1210] Power [kW]
Actual power consumed by the motor
in kW.
[1211] Power [hp]
Actual power consumed by the motor
in HP.
[1212] Motor Rated
Voltage supplied to the motor.
Voltage
[1213] Frequency
Motor frequency, i.e. the output
frequency from the frequency converter
in Hz
[1214] Motor Current
Phase current of the motor measured as
effective value.
[1215] Frequency [%]
Motor frequency, i.e. the output
frequency from the frequency converter
in percent.
[1216] Torque [Nm]
Present motor load as a percentage of
the rated motor torque.
[1217] Speed [RPM]
Motor speed reference. Actual speed
will depend on slip compensation being
used (compensation set in
parameter P-09 Slip Compensation). If not
used, actual speed will be the value
read in the display minus motor slip.
[1218] Motor Thermal
Thermal load on the motor, calculated
by the Electronic Thermal Overload
function. See also parameter group H-9#
Motor Temperature.
[1222] Torque [%]
Shows the actual torque produced, in
percentage.
[1230] DC Link Voltage Intermediate circuit voltage in the
frequency converter.
[1232] Brake Energy /s
Present brake power transferred to an
external brake resistor. Stated as an
instantaneous value.
[1233] Brake Energy /2
Brake power transferred to an external
min
brake resistor. The mean power is
calculated continuously for the most
recent 120 seconds.
[1234] Heatsink Temp.
Present heat sink temperature of the
frequency converter. The cut-out limit is
95 ± 5° C; cutting back in occurs at 70
± 5° C.
[1235] Drive Thermal
Percentage load of the inverters.
[1236] Drive Nominal
Nominal current of the frequency
Current
converter.
[1237] Drive Max.
Maximum current of the frequency
Current
converter.
[1238] Logic Controller
State of the event executed by the
State
control.
[1239] Control Card
Temperature of the control card.
Temp.
[1250] External
Sum of the external reference as a
Reference
percentage, i.e. the sum of analog/