GE Ecomagination AF-600 FP Programming Manual page 121

Fan & pump drive
Table of Contents

Advertisement

Parameter Description
DR-85 Drive Port CTW 1
Range:
0
[0 -
*
65535]
3
3
DR-86 Drive Port REF 1
Range:
0
[-200 -
*
200]
3.17.7 DR-9# Diagnosis Readouts
NOTICE
When using DCT-10, the readout parameters can only be
read online, that is as the actual status. This means that
the status is not stored in the DCT-10 file.
DR-90 Alarm Word
Range:
0
[0 - 4294967295] Shows the alarm word sent via the serial
*
DR-91 Alarm Word 2
Range:
0
[0 - 4294967295] View the alarm word 2 sent via the serial
*
DR-92 Warning Word
Range:
0
[0 - 4294967295] Shows the warning word sent via the
*
DR-93 Warning Word 2
Range:
0
[0 - 4294967295] View the warning word 2 sent via the
*
DR-94 Ext. Status Word
Range:
0
[0 - 4294967295] Returns the extended status word sent via
*
120
Function:
View the 2-byte control word (CTW) received
from the fieldbus master. Interpretation of the
control word depends on the fieldbus option
installed and the control word profile selected
in parameter O-10 Control Word Profile.
Function:
View the 2-byte status word (STW) sent to the
fieldbus master. Interpretation of the status word
depends on the network option installed and the
control word profile selected in
parameter O-10 Control Word Profile.
Function:
communication port in hex code.
Function:
communication port in hex code.
Function:
serial communication port in hex code.
Function:
serial communication port in hex code.
Function:
the serial communication port in hex
code.
DR-95 Ext. Status Word 2
Range:
0
[0 - 4294967295] Returns the extended warning word 2
*
DR-96 Maintenance Word
Range:
0
[0 -
*
4294967295]
03/2016 All rights reserved.
Function:
sent via the serial communication port in
hex code.
Function:
Readout of the preventive maintenance word.
The bits reflect the status for the
programmed preventive maintenance events
in parameter group T-1#. 13 bits represent
combinations of all the possible items:
Bit 0: Motor bearings.
Bit 1: Pump bearings.
Bit 2: Fan bearings.
Bit 3: Valve.
Bit 4: Pressure transmitter.
Bit 5: Flow transmitter.
Bit 6: Temperature transmitter.
Bit 7: Pump seals.
Bit 8: Fan belt.
Bit 9: Filter.
Bit 10: Frequency converter cooling
fan.
Bit 11: Frequency converter system
health check.
Bit 12: Warranty.
Bit 13: Maintenance Text 0.
Bit 14: Maintenance Text 1.
Bit 15: Maintenance Text 2.
Bit 16: Maintenance Text 3.
Bit 17: Maintenance Text 4.
DET-620D