Cl-## Pid Closed Loop - GE Ecomagination AF-600 FP Programming Manual

Fan & pump drive
Table of Contents

Advertisement

Parameter Lists
Par. No. #
Parameter description
T-04
Occurrence
T-08
Timed Actions Mode
T-09
Timed Actions Reactivation
T-1#
T-10
Maintenance Item
T-11
Maintenance Action
T-12
Maintenance Time Base
T-13
Maintenance Time Interval
T-14
Maintenance Date and Time
T-15
Reset Maintenance Word
T-16
Maintenance Text
T-5#
T-50
Energy Log Resolution
T-51
Period Start
T-53
Energy Log
T-54
Reset Energy Log
T-6#
T-60
Trend Variable
T-61
Continuous Bin Data
T-62
Timed Bin Data
T-63
Timed Period Start
T-64
Timed Period Stop
T-65
Minimum Bin Value
T-66
Reset Continuous Bin Data
T-67
Reset Timed Bin Data
T-8#
T-80
Power Reference Factor
T-81
Energy Cost
T-82
Investment
T-83
Energy Savings
T-84
Cost Savings

5.1.23 CL-## PID Closed Loop

Par. No. #
Parameter description
CL-0#
CL-00
Feedback 1 Source
CL-01
Feedback 1 Conversion
CL-02
Feedback 1 Source Unit
CL-03
Feedback 2 Source
CL-04
Feedback 2 Conversion
CL-05
Feedback 2 Source Unit
CL-06
Feedback 3 Source
CL-07
Feedback 3 Conversion
CL-08
Feedback 3 Source Unit
CL-1#
CL-12
Reference/Feedback Unit
CL-13
Minimum Reference/Feedb.
CL-14
Maximum Reference/Feedb.
CL-2#
DET-620D
AF-600 FP™ Programming Guide
Default value
4-set-up
[0] All days
2 set-ups
[0] Timed Actions Auto
2 set-ups
[1] Enabled
2 set-ups
[1] Motor bearings
1 set-up
[1] Lubricate
1 set-up
[0] Disabled
1 set-up
1 h
1 set-up
ExpressionLimit
1 set-up
[0] Do not reset
All set-ups
0 N/A
1 set-up
[5] Last 24 Hours
2 set-ups
ExpressionLimit
2 set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
[2] Frequency [Hz]
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[0] Do not reset
All set-ups
[0] Do not reset
All set-ups
100 %
2 set-ups
1 N/A
2 set-ups
0 N/A
2 set-ups
0 kWh
All set-ups
0 N/A
All set-ups
Default value
[2] Analog Input 54
[0] Linear
ExpressionLimit
[0] No function
[0] Linear
ExpressionLimit
[0] No function
[0] Linear
ExpressionLimit
ExpressionLimit
0 ProcessCtrlUnit
100 ProcessCtrlUnit
03/2016 All rights reserved.
Change during
Conver-
operation
sion index
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
74
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
-2
TRUE
0
TRUE
75
TRUE
0
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
TimeOfDay
5
5
Uint8
VisStr[20]
Uint8
TimeOfDay
Uint32
Uint8
Uint8
Uint32
Uint32
TimeOfDay
TimeOfDay
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
Int32
Int32
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Int32
-3
Int32
229