Parameter Description
3.25.6 LC-5# States
LC-51 Logic Controller Event
Array [20]
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Line voltage out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
Logic Controller Time-out 0
[31]
Logic Controller Time-out 1
[32]
Logic Controller Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
DET-620D
AF-600 FP™ Programming Guide
Function:
Select the boolean input
(TRUE or FALSE) to define the
logic controller event.
See parameter LC-02 Stop
Event for further descriptions
of options and their functions.
03/2016 All rights reserved.
LC-51 Logic Controller Event
Array [20]
Option:
[42]
Auto Reset Trip
[43]
OK Key
[44]
Reset Key
[45]
Left Key
[46]
Right Key
[47]
Up Key
[48]
Down Key
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
Logic Controller Time-out 3
[71]
Logic Controller Time-out 4
[72]
Logic Controller Time-out 5
[73]
Logic Controller Time-out 6
[74]
Logic Controller Time-out 7
[76]
Digital Input x30 2
[77]
Digital Input x30 3
[78]
Digital Input x30 4
[80]
No Flow
[81]
Dry Pump
[82]
End of Curve
[83]
Broken Belt
[90]
ECB Drive Mode
[91]
ECB Bypass Mode
[92]
ECB Test Mode
[100] Fire Mode
[140] ATEX ETR cur. warning
[141] ATEX ETR cur. alarm
[142] ATEX ETR freq. warning
[143] ATEX ETR freq. alarm
LC-52 Logic Controller Action
Array [20]
Option:
Function:
Select the action corresponding to the
LC event. Actions are executed when the
corresponding event (defined in
parameter LC-51 Logic Controller Event) is
evaluated as true. The following actions
are available for selection:
[0]
Disabled
*
[1]
No action
[2]
Select set-up 1
Changes the active set-up
(parameter K-10 Active Set-up) to 1.
[3]
Select set-up 2
Changes the active set-up
(parameter K-10 Active Set-up) to 2.
Function:
See parameter LC-15 RS-FF
Operand S,
parameter LC-16 RS-FF
Operand R.
191