Parameter Description
XC-32 Ext. 2 Maximum Reference
Range:
100
ExtPID2Unit
*
3
3
XC-33 Ext. 2 Reference Source
Option:
[0]
No function
*
[1]
Analog Input 53
[2]
Analog Input 54
[7]
Pulse input 29
[8]
Pulse input 33
[20] Digital Potentiometer
[21] Analog input X30/11
[22] Analog input X30/12
[23] Analog Input X42/1
[24] Analog Input X42/3
[25] Analog Input X42/5
[30] Ext. Closed Loop 1
[31] Ext. Closed Loop 2
[32] Ext. Closed Loop 3
XC-34 Ext. 2 Feedback Source
Option:
[0]
No function
*
[1]
Analog Input 53
[2]
Analog Input 54
[3]
Pulse input 29
[4]
Pulse input 33
[7]
Analog Input X30/11
[8]
Analog Input X30/12
[9]
Analog Input X42/1
[10]
Analog Input X42/3
[11]
Analog Input X42/5
[100] Bus Feedback 1
[101] Bus Feedback 2
[102] Bus feedback 3
XC-35 Ext. 2 Setpoint
Range:
0 ExtPID2Unit
*
XC-37 Ext. 2 Reference [Unit]
Range:
0 ExtPID2Unit
*
170
Function:
[par. XC-31 -
See parameter XC-12 Ext. 1
999999.999
Maximum Reference for
ExtPID2Unit]
details.
Function:
See parameter XC-13 Ext. 1 Reference
Source for details.
Function:
See parameter XC-14 Ext. 1 Feedback
Source for details.
Function:
[par. XC-31 - par.
See parameter XC-15 Ext. 1
XC-32 ExtPID2Unit]
Setpoint for details.
Function:
[-999999.999 -
See parameter XC-17 Ext. 1
999999.999
Reference [Unit], Ext. 1
ExtPID2Unit]
Reference [Unit], for details.
XC-38 Ext. 2 Feedback [Unit]
Range:
0 ExtPID2Unit
XC-39 Ext. 2 Output [%]
Range:
0 %
[0 - 100 %] See parameter XC-19 Ext. 1 Output [%] for
*
3.23.5 XC-4# Ext. CL 2 PID
XC-40 Ext. 2 Normal/Inverse Control
Option:
[0]
Normal
*
[1]
Inverse
XC-41 Ext. 2 Proportional Gain
Range:
0.01
[0 - 10] See parameter XC-21 Ext. 1 Proportional Gain for
*
XC-42 Ext. 2 Integral Time
Range:
10000 s
[0.01 - 10000 s] See parameter XC-22 Ext. 1 Integral
*
XC-43 Ext. 2 Differentation Time
Range:
0 s
[0 - 10 s] See parameter XC-23 Ext. 1 Differentation Time for
*
XC-44 Ext. 2 Dif. Gain Limit
Range:
5
[1 - 50] See parameter XC-24 Ext. 1 Dif. Gain Limit for details.
*
3.23.6 XC-5# Ext. CL 3 Ref./Fb.
XC-50 Ext. 3 Ref./Feedback Unit
Option:
[0]
[1]
%
*
[5]
PPM
[10]
1/min
[11]
RPM
[12]
Pulse/s
[20]
l/s
03/2016 All rights reserved.
Function:
[-999999.999 -
See parameter XC-18 Ext. 1
*
999999.999
Feedback [Unit] for details.
ExtPID2Unit]
Function:
details.
Function:
See parameter XC-20 Ext. 1 Normal/Inverse Control
for details.
Function:
details.
Function:
Time for details.
Function:
details.
Function:
Function:
See parameter XC-10 Ext. 1 Ref./Feedback Unit for
details.