Parameter Description
F-52 Minimum Reference
Range:
Function:
obtainable by summing all references.
This value defines the lower limit for
both the local and remote reference
depending on the choice in par. F-02
Operation Method.
NOTICE
This parameter is used in open
loop only.
F-53 Maximum Reference
Range:
Function:
60.000
[par. F-52 -
Enter the Maximum Reference. The
*
999999.999]
Maximum Reference is the highest
obtainable by summing all references.
This value defines the upper limit for
both the local and remote reference
depending on the choice in par. F-02
Operation Method.
F-54 Reference Function
Option:
Function:
[0]
Sum
Sums both external and preset reference
sources.
[1]
External/
Use either the preset or the external
*
Preset
reference source.
Shift between external and preset via a
command on a digital input.
3.2.8 F-6# References
F-64 Preset Relative Reference
Range:
Function:
0 %
[-100
The actual reference, X, is increased or decreased
-
with the percentage Y, set in parameter F-64 Preset
*
100 %]
Relative Reference. This results in the actual
reference Z. Actual reference (X) is the sum of the
inputs selected in:
Parameter F-01 Frequency Setting 1.
Parameter C-30 Frequency Command 2.
Parameter C-34 Frequency Command 3.
Parameter O-02 Control Word Source.
Illustration 3.11 Preset Relative Reference
DET-620D
AF-600 FP™ Programming Guide
Illustration 3.12 Actual Reference
3.2.9 F-9# Digital Potentiometer
The digital potentiometer function allows the user to
increase or decrease the actual reference by adjusting the
set-up of the digital inputs using the functions INCREASE,
DECREASE or CLEAR. To activate the function, at least one
digital input must be set up to INCREASE or DECREASE.
F-90 Step Size
Range:
0.10 %
*
F-91 Accel/Decel Time
Range:
1 s
[0 -
3600 s]
F-92 Power Restore
Option: Function:
[0]
Off Resets the digital pot-meter reference to 0% after
*
[1]
On
03/2016 All rights reserved.
Function:
[0.01 -
Enter the increment size required for
200 %]
increase/decrease as a percentage of the
synchronous motor speed, n
decrease is activated, the resulting reference
is increased or decreased by the value set in
this parameter.
Function:
Enter the ramp time, that is the time for
adjustment of the reference 0–100% of the
specified digital potentiometer function (increase,
decrease, or clear).
If increase/decrease is activated for longer than the
ramp delay period specified in parameter F-95 Accel/
Decel Ramp Delay, the actual reference is acceled/
deceled according to this ramp time. The ramp
time is defined as the time spent to adjust the
reference by the step size specified in
parameter F-90 Step Size.
power-up.
Restores the most recent digital pot-meter reference at
power-up.