GE Ecomagination AF-600 FP Programming Manual page 148

Fan & pump drive
Table of Contents

Advertisement

Parameter Description
T-10 Maintenance Item
Array [20]
Option:
Function:
[12] System health check
[13] Warranty
[20] Maintenance Text 0
[21] Maintenance Text 1
[22] Maintenance Text 2
[23] Maintenance Text 3
[24] Maintenance Text 4
[25] Maintenance Text 5
T-11 Maintenance Action
Array [20]
Option:
Function:
Select the action to be associated with
the preventive maintenance event.
[1]
Lubricate
*
[2]
Clean
[3]
Replace
[4]
Inspect/Check
[5]
Overhaul
[6]
Renew
[7]
Check
[20] Maintenance Text 0
[21] Maintenance Text 1
[22] Maintenance Text 2
[23] Maintenance Text 3
[24] Maintenance Text 4
[25] Maintenance Text 5
T-12 Maintenance Time Base
Array [20]
Option:
Function:
Select the time base to be associated with the
preventive maintenance event.
[0]
Disabled
Disables the preventive maintenance event.
*
[1]
Running
The number of hours the motor has run.
Hours
Running hours are not reset at power-on.
Specify the maintenance time interval in
parameter T-13 Maintenance Time Interval.
[2]
Operating
The number of hours the frequency converter
Hours
has run. Operating hours are not reset at
power-on. Specify the maintenance time
interval in parameter T-13 Maintenance Time
Interval.
[3]
Date &
Uses the internal clock. Specify the date and
Time
time of the next maintenance occurrence in
parameter T-14 Maintenance Date and Time.
DET-620D
AF-600 FP™ Programming Guide
T-13 Maintenance Time Interval
Array [20]
Range:
1
[1 -
h
2147483647
*
h]
T-14 Maintenance Date and Time
Array [20]
Range:
0
[0 -
*
0]
03/2016 All rights reserved.
Function:
Set the interval associated with the current
preventive maintenance event. This
parameter is only used if [1] Running Hours or
[2] Operating Hours is selected in
parameter T-12 Maintenance Time Base. The
timer is reset from parameter T-15 Reset
Maintenance Word.
Example
A preventive maintenance event is set up
Monday at 8:00. Parameter T-12 Maintenance
Time Base is [2] Operating hours and
parameter T-13 Maintenance Time Interval is 7
x 24 hours=168 hours. Next maintenance
event is indicated the following Monday at
8:00. If this maintenance event is not reset
until Tuesday at 9:00, the next occurrence is
the following Tuesday at 9:00.
Function:
Set the date and time for next maintenance
occurrence if the preventive maintenance event is
based on date/time. Date format depends on the
setting in parameter K-71 Date Format while the
time format depends on the setting in
parameter K-72 Time Format.
NOTICE
The frequency converter has no back-up of
the clock function and the set date/time is
reset to default (2000-01-01 00:00) after a
power-down. In parameter K-79 Clock Fault, it
is possible to programme a warning if the
clock has not been set properly, for example
after a power-down.
Set the time at least 1 hour later than actual
time!
NOTICE
When mounting an Analog I/O option option
card, a battery back-up of the date and time
is included.
3
3
147

Advertisement

Table of Contents
loading

Table of Contents