GE Ecomagination AF-600 FP Programming Manual page 102

Fan & pump drive
Table of Contents

Advertisement

Parameter Description
PB-71 Profibus Save Data Values
Option:
Function:
Parameter values changed via PROFIBUS are not
automatically stored in non-volatile memory.
Use this parameter to activate a function that
stores parameter values in the EEPROM non-
volatile memory, so changed parameter values
are retained at power-down.
[0]
Off
Deactivates the non-volatile storage function.
*
[1]
Store edit
Stores all parameter values for all set-ups in the
setup
non-volatile memory. When all parameter values
have been stored, the selection returns to [0]
Off.
[2]
Store all
Stores all parameter values for all set-ups in the
setups
non-volatile memory. When all parameter values
have been stored, the selection returns to [0]
Off.
PB-72 ProfibusDriveReset
Option:
Function:
[0]
No action
*
[1]
Power-on
Resets the frequency converter after power-
reset
up, as for power-cycle.
[2]
Power-on
reset prep
[3]
Comm
Resets the PROFIBUS DP option only. This is
option reset
useful after changing certain settings in
parameter group PB-##, for example,
parameter PB-18 Node Address.
When reset, the frequency converter
disappears from the Network, which may
cause a communication error from the master.
PB-75 DO Identification
Range:
Function:
0
[0 - 65535] Provides information about the DO (Drive
*
Object).
PB-80 Defined Parameters (1)
Array [116]
No keypad access
Read only
Range:
Function:
0
[0 - 9999] This parameter shows a list of all the defined
*
frequency converter parameters available for
PROFIBUS.
DET-620D
AF-600 FP™ Programming Guide
PB-81 Defined Parameters (2)
Array [116]
No keypad access
Read only
Range:
0
[0 - 9999] This parameter shows a list of all the defined
*
PB-82 Defined Parameters (3)
Array [116]
No keypad access
Read only
Range:
0
[0 - 9999] This parameter shows a list of all the defined
*
PB-83 Defined Parameters (4)
Array [116]
No keypad access
Read only
Range:
0
[0 - 9999] This parameter shows a list of all the defined
*
PB-84 Defined Parameters (5)
Array [115]
No LCP access
Read only
Range:
0
[0 - 9999] This parameter displays a list of all the defined
*
PB-85 Defined Parameters (6)
Range:
0
*
PB-90 Changed Parameters (1)
Array [116]
No keypad access
Read only
Range:
0
[0 - 9999] This parameter shows a list of all the frequency
*
03/2016 All rights reserved.
Function:
frequency converter parameters available for
PROFIBUS.
Function:
frequency converter parameters available for
PROFIBUS.
Function:
frequency converter parameters available for
PROFIBUS.
Function:
frequency converter parameters available for
PROFINET.
Function:
[0 - 9999]
Function:
converter parameters deviating from default
setting.
3
3
101