Single phase smart meter
Table of Contents

Advertisement

AS302P
S
P
S
M
INGLE
HASE
MART
ETER
O
I
PERATING
NSTRUCTIONS
M450 001 1D
23
M
2019
RD
AY

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell AS302P

  • Page 1 AS302P INGLE HASE MART ETER PERATING NSTRUCTIONS M450 001 1D 2019...
  • Page 2 Honeywell. No part of this document may be reproduced, transmitted, transcribed, stored in any retrieval system, or translated into any language by any means, electronic or mechanical, including photocopying and recording, for any purpose other than the licensee's personal use without the express written permission of Honeywell.
  • Page 3 Disclaimer The information contained in this message (including any attachments) is confidential and intended solely for the attention and use of the named addressee(s). It must not be disclosed to any person without our authority. If you are not the intended recipient, please delete it from your system immediately - any disclosure, copying or distribution thereof or any action taken or omitted to be taken in reliance thereon is prohibited and may be unlawful.
  • Page 5: Table Of Contents

    COST OF INSTANTANEOUS CONSUMPTION ..............22 POWER THRESHOLD STATUS ................... 22 PROFILES ..........................23 Profile 1 – Profile Data Log Import ..................23 16.1. 16.2. Profile 2 - Profile Data Log Export ..................23 © Honeywell - M450 001 1D - 23.05.2019...
  • Page 6 Firmware Download Process ....................37 22.3.1. Distribution of the Image ................... 37 22.3.2. Verification of the Image ................... 37 22.3.3. Activation of the Image ..................... 38 22.3.4. Restrictions ....................... 38 22.3.5. Firmware identification format .................. 38 © Honeywell - M450 001 1D - 23.05.2019...
  • Page 7 Payment Based Debt Collection ..................... 65 34.10. UTRN Processing ........................66 34.11. Emergency Credit Transitions ....................67 APPENDICES ........................69 35.1. APPENDIX A - Checking kWh and kvarh Registration Accuracy ........... 69 © Honeywell - M450 001 1D - 23.05.2019...
  • Page 8 AS302P Single Phase Smart Meter ____________________________________________________________________ 35.2. APPENDIX B - Event/Alarm Logs ..................71 APPENDIX C – Interface Commands ..................75 35.3. APPENDIX D – Data ......................77 35.4. GLOSSARY ........................... 80 © Honeywell - M450 001 1D - 23.05.2019...
  • Page 9: Foreword

    Products supplied by Honeywell have been designed and manufactured, in accordance with appropriate standards, to operate under specified conditions, when properly installed. The purchaser or delegated contractor is responsible for the "Putting into Service" of any Honeywell products that have been supplied as "Non-connected".
  • Page 10 Honeywell would like to draw the user's attention to the International Standard for Lithium Batteries - IEC 60086-4 - which gives further information about the handling, storage, transport and disposal of lithium cells.
  • Page 11: Compliance With Standards And European Directives

    The meter complies with Class M2 Mechanical environment and Class E2 Electromagnetic Environment as defined in the Measuring Instruments Directive 2014/32/EU. The AS302P meter has been designed and manufactured to comply with the relevant requirements of the following Directives and Specifications.
  • Page 12: Approvals

    Great Britain Companion Specification - sec-5-0-schedule-8---gb- companion-specification 4. APPROVALS Type Approvals under the Measurement Instrument Directive and Radio equipment Directive are given by SGS following assessment against the relevant standards listed above. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 13: Introduction

    This Manual covers the features of the AS302P SMETS2 product. The SMETS2 meter is designed specifically for the UK market and conforms to all DECC published requirements (GBCS V1.1, SMETS2 v2.0). The AS302P is a Multi-tariff Residential Smart Meter that can be programmed by the Supplier to operate as a Credit or Prepayment Meter.
  • Page 14 48 TOU Import kWh • 8 TOU x 4 Blocks Import kWh • 4 Seasons • 4 Week Profiles • 16 Day Profiles • 200 Switching Points • 50 Special Days • Deferred Tariff Program © Honeywell - M450 001 1D - 23.05.2019...
  • Page 15: General Description

    Import (+R) kvarh Export (-R) 6.4. Meter Accuracy The AS302P meter measures Active Energy, in accordance with the requirements of: • EU Directive 2014/32/EU (MID) - Class A or Class B (EN 50470-1, EN 50470-3) The meter measures Reactive Energy in accordance of the requirements of: •...
  • Page 16: Meter Case

    Magnetic Field Detection The AS302P has a sensor which detects if a Strong Magnetic Field has been detected or removed. The detection or removal of a Magnetic Field is logged in the Security Log with a Time and Date Stamp.
  • Page 17: Features

    Note: The diagram shows a representation of the quadrants. The quadrant of the present load can be shown on the display. 8.2. Demand Registers A Demand Register is associated with the Import and Export kWh Registers. The Demand Period is set at 30 minutes. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 18: Operating Modes

    AS302P Single Phase Smart Meter ____________________________________________________________________ 9. OPERATING MODES The AS302P can be configured to operate in Credit or Prepayment Mode. If no parameters are sent the meter will remain as programmed during Manufacture. The following mode switching configurations are available: Credit to Prepayment...
  • Page 19: Restrict Data

    Randomised Offset Limit (A value in seconds in the range 0 to 1799) Randomised Offset Number (A randomly generated value between 0 and 1) 11.2.1. TOU Mode Independent Switching for 48 TOU Registers based on Imp KWh. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 20: Tariff Switching Table

    There is a maximum of 4 Week Profiles. A minimum of one Week Profile is required for tariff operation. A Day Profile is required to be defined for each day of the week. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 21: Day Profiles

    Type 1 or Type 2 Devices. Price Information is also used for the Prepayment Application and to calculate Cost Information. The AS302P contains the ‘Active’ and a ‘Deferred’ Price Matrix which must be configured for each TOU Rate. The Price Matrix is for Import Active Energy only.
  • Page 22: Tou Block Price Matrix

    The TOU Block Price Matrix can be programmed to be activated at a specified Activation Date/Time. The TOU Block Price Matrix for the TOU Block Tariff is shown below: 11.3.2. Maximum Demands The AS302P calculates and stores the following Maximum Demands: • Maximum Demand Active Power Import Value •...
  • Page 23 Maximum Demand Active Power Export Value This stores the largest Average Value of Active Power Export recorded in any 30 Minute Period since it was last reset, along with its UTC Time of Occurrence. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 24: Billing Data

    Tariff TOU Registers • Tariff TOU Block Registers • Active Import Register • Meter Balance • Emergency Credit Balance • Accumulated Debt • Remaining Payment Debt • Remaining Time Debt 1 and 2 © Honeywell - M450 001 1D - 23.05.2019...
  • Page 25: Payment Billing Data Log

    12.2.2. Export Daily Read Log • Active Export Register 12.2.3. Prepayment Daily Read Log • Meter Balance • Emergency Credit Balance • Accumulated Debt • Remaining Payment Debt • Remaining Time Debt 1 and 2 © Honeywell - M450 001 1D - 23.05.2019...
  • Page 26: Customer Cost Information

    AS302P Single Phase Smart Meter ____________________________________________________________________ 13. CUSTOMER COST INFORMATION 13.1. Consumption Data The AS302P stores the following data for Daily, Weekly and Monthly Billing: • Import kWh • Estimated Cost for kWh Import Daily Cost is calculated by taking the advance in each TOU or TOU Block Register and multiplying this by the Current Price plus Standing Charge.
  • Page 27: Profiles

    Average RMS Voltage, over a Configurable Period. 4320 entries 16.5. Profile 5 – Daily Consumption log kWh Import – Amount of kWh consumed in a Day - Captured at Midnight UTC - 731 Days Storage © Honeywell - M450 001 1D - 23.05.2019...
  • Page 28: Prepayment Mode

    Disablement Threshold during periods on non-disconnection as defined by the Non-disconnection calendar. If this situation occurs an Alert will be sent by the HAN. See 34.9 for operation of the Disablement Threshold. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 29: Add Credit

    UTRNs / PTUTs are being entered on a regular basis. 17.4.1. Credit Top Up – WAN / HAN PTUTs can be sent via the DCC to the meter. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 30: Manual Entry Credit Top Up

    Payment Based Debt (subject to Debt Recovery Cap – See Section 17.7.2) Accumulated Debt (See Section 17.7.3) Emergency Credit Used (See Section 17.7.5) See 34.10 for the logical operation of the TopUp Allocation. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 31: Emergency Credit

    2 Week Profiles, each containing a maximum of 2 Day Profiles • Three Seasons Dates and Days operate from Midnight to Midnight and the Time of Day applies to all other days not specified by a Date or Day. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 32: Debt Collection

    The Aggregated Debt = Debt 1 Outstanding + Debt 2 Outstanding + Debt 3 Outstanding. 17.7.5. Debt to Clear Debt to Clear is calculated by the meter as: Difference between the Meter Balance and the Disablement Threshold plus Amount of Accumulated Debt plus © Honeywell - M450 001 1D - 23.05.2019...
  • Page 33: Debt Collection Suspension Settings

    When operating in Prepayment Mode this will take presidency for Opening the Contactor. Once the value for active power reaches 90% of the Load Limit Threshold the meter should trigger an audible alarm (configurable during manufacturing only). © Honeywell - M450 001 1D - 23.05.2019...
  • Page 34: Display And Pushbuttons

    The display has the following 2 possible modes of operation, either of which can be configured at manufacture only: Scroll Mode If Scroll Mode is set up to 40 items can be configured. Menu Mode If Menu Mode is set 34.6 shows all displayable items available. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 35: Scroll Mode

    The Tariff TOU Register Matrix or the Tariff TOU Block Register Matrix and the Tariff Block Counter Matrix; • The Active Import Register; • The Active Export Register; • The Meter Balance [PIN]; • The Debt to Clear [PIN]; © Honeywell - M450 001 1D - 23.05.2019...
  • Page 36: Display Configuration

    The Backlight will turn ‘On’ when a Pushbutton is pressed. The Backlight turns ‘Off’ after a configurable (during Manufacture) number of seconds after the last Pushbutton Press. During the Installation Process the Backlight will be ‘On’. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 37: Display Indicators

    An event will be created in the Event Log (with appropriate code) when the PIN is disabled or changed via the Pushbuttons. Honeywell suggests that the Utility providing the meter includes in its User Guide advice on: selection, secure handling or entry of the user PIN.
  • Page 38: Power Quality Monitoring

    If the time between the Power Fail and the Power Restoration is equal to or greater than 3mins, then this will be logged as a long Power Fail Event (with UTC Time & Date Stamp) in the Power Event Log. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 39: Communications

    21.2. Direct Communications Connection to the Comms Hub The Comms Hub Interface allows provision for a Hardwired Interface between the Meter and the Module. This feature is not supported by the AS302P meter. 21.3. HAN Communications Connections to the Comms Hub The meter provides a HAN Interface that conforms to the following standards: ZigBee Alliance as compliant with the ZigBee SEP v1.2b...
  • Page 40: Communications With Dcc

    AS302P Single Phase Smart Meter ____________________________________________________________________ • On joining a ZigBee SEP v1.2 Smart Metering Home Area Network, the AS302P is capable of generating and sending an Alert to that effect via its HAN Interface. • Restricting Personal Data Available for Type 1 and Type 2 Devices from a defined UTC Date and Time •...
  • Page 41: Firmware

    The Comms Hub notifies the AS302P that a New Firmware Image is available • The AS302P downloads the new Image, via the ZigBee OTA process, when it is aware of the availability of a suitable Upgrade Image 22.3.2. Verification of the Image •...
  • Page 42: Activation Of The Image

    • The AS302P verifies its Firmware at every Power On to check that it is the same as the last Verified and Running Firmware. If the verification fails then an entry in the Security Log will be made and an Alert will be generated on the HAN.
  • Page 43: Operating & Maintenance Instructions

    If the Main Meter Contactor is open the ALCS or HCALCS cannot be closed. If the power is restored to the meter and a command should have been in operation, then this operation runs for the remaining period. If there is a command received this takes precedence over the ALCS Switching Calendar. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 44: Auxiliary Load Control Switch Calendar

    A command to control the state of the HCALCS, in accordance with the rules of the ALCS Switching Calendar, this will contain the remaining time until the next Switching Event (taking into account the Randomised Offset). © Honeywell - M450 001 1D - 23.05.2019...
  • Page 45: Boost Functionality

    Test Auxiliary Load Control Switch [n] command All commands, except the third one (Revert to Calendar), have as a result two entries captured in the ALCS event log (Revert to Calendar triggers three entries). © Honeywell - M450 001 1D - 23.05.2019...
  • Page 46: Contactor

    25. CONTACTOR A single pole, 100A Contactor is provided in the AS302P. Contactor Technical Details are given in Section 29.2. Note that in normal use, the user can Enable the Supply if the Contactor state is Ready for connection (Armed) using the meter display.
  • Page 47: Internal Clock

    __________________________________________________________________________ 26. INTERNAL CLOCK The AS302P compares its Time with the Comms Hub and adjusts as necessary. No event is recorded, providing the time difference is no greater than 10s. If the Time Difference is greater than 10s then the meter does not adjust its time but generates an Event in the Security Log and sends an Alert over the HAN.
  • Page 48: Security Credentials

    (based on the command outcome). 27.2. Security Credentials The AS302P generates Public-Private Keys to support Cryptographic Algorithms, initiated by a Command. These are the Device, Signing and Key Agreement Certificates. Once a device has been installed then the Supplier should send an ‘Issue Security Credentials Command’ to the meter within seven days of installation.
  • Page 49: Confidentiality And / Or Data Integrity

    The Meter employs techniques to protect against Replay Attacks, on any communications. 27.6. Security Log The AS302P has a Security Log to store any Security Related Events (See Section 28), this Log cannot be cleared unless the Physical Boundary is breached.
  • Page 50: Meter Logs

    AS302P Single Phase Smart Meter ____________________________________________________________________ 28. METER LOGS The AS302P stores a number of Event Logs to record events that have occurred in the Metering Device. These Logs are: • Security Log • Event Log • Power Quality Log All Logs are stored on a FIFO basis and each event is stored with a UTC Date and Time Stamp.
  • Page 51: Technical Data

    IEC 62053-21, Class 1 or Class 2 Case BS 7856:2013 IP53 to IEC 60529:1989 Terminals Main 8.2mm Diameter Bore, 2 x M6 Combi Pinch Screws (Screw Material - Steel, Coated with Zinc Chromate) Max Torque 2.8 N m © Honeywell - M450 001 1D - 23.05.2019...
  • Page 52: Contactor

    440 VAC Maximum Switching Current 100A Mechanical Life 10,000 Operations (BS EN 62055-31, Annex C) Standards Short Circuit Withstand BS EN 62055-31, UC3 Overcurrent Withstand BS 7856:2013. 120A Continuous, 145A for 2 Hours © Honeywell - M450 001 1D - 23.05.2019...
  • Page 53: Installation, Commissioning And Decommisioning

    Scan for tunnel AS302P sends NWK Join Request with Certificate Based Key Exchange AS302P and IHD join HAN with ZigBee Network and Link Connections to Comms Hub. There is no IHD to AS302P data at this stage. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 54: Meter Installation - Temp No Wan

    HHT needs a robust connection to Suppliers Systems to make the Installation Viable due to sequencing of Commands and Responses – The AS302P is likely to remain on its Own Time (from factory) but identified in GBCS terms as “Unreliable” until a Comms Hub WAN connection is established –...
  • Page 55: Installation And Commissioning Of Hardware

    31.5. Electromagnetic Compatibility (EMC) The AS302P meter has been designed and tested for compliance with the EMC Directive. It is, however, the responsibility of the installer for ensuring that a system conforms to the Directive.
  • Page 56: Fixing And Connection

    26mm. The terminal block dimensions on the AS302P meter have a maximum sectional area of 50mm Fully insert cables into the terminals so that the insulation butts up into the counter-sunk recesses in the bottom face of the terminal block.
  • Page 57: Commissioning

    Honeywell would like to draw the user's attention to the International Standard for Lithium Batteries - IEC 60086-4 which gives further information about the handling, storage, transport and disposal of Lithium cells.
  • Page 58: Figures & Tables

    AS302P Single Phase Smart Meter ____________________________________________________________________ 34. FIGURES & TABLES 34.1. Sample Model Code Pulse Output Values For all meter ratings the normal pulse value for the Test LED will be 4000 pulses / kWh (kvarh). © Honeywell - M450 001 1D - 23.05.2019...
  • Page 59: As302P Front View

    Operating & Maintenance Instructions __________________________________________________________________________ 34.2. AS302P Front View © Honeywell - M450 001 1D - 23.05.2019...
  • Page 60: As302P Example Nameplate

    AS302P Single Phase Smart Meter ____________________________________________________________________ 34.3. AS302P Example Nameplate Note: The Nameplate will be laser printed on the cover © Honeywell - M450 001 1D - 23.05.2019...
  • Page 61: Terminal Arrangements / Wiring Diagram

    Operating & Maintenance Instructions __________________________________________________________________________ 34.4. Terminal arrangements / wiring diagram © Honeywell - M450 001 1D - 23.05.2019...
  • Page 62: Dimensions And Fixing Centres

    AS302P Single Phase Smart Meter ____________________________________________________________________ 34.5. Dimensions and Fixing Centres © Honeywell - M450 001 1D - 23.05.2019...
  • Page 63: Displayable Items

    (if configured) before its content MPAN Import Meter Point Administration Number (Combined ✓ ✓ MPANS) MPAN Export Meter Point Administration Number (Export ✓ ✓ MPANS) Customer ✓ ✓ Customer ID Customer Identification Number xxxx Contactor © Honeywell - M450 001 1D - 23.05.2019...
  • Page 64 Level 4 Description Display Format Credit Prepay Scroll Mode Mode Mode PIN Mode Disable PIN Only shown if PIN Enabled One of the following enabled PIN Status Disable Privacy PIN Protection Set PIN © Honeywell - M450 001 1D - 23.05.2019...
  • Page 65 Event Code xxxxH Security Log ONLY available if cover is open dd-mm-yy – hh:mm ✓ ✓ Log 1 Time Date Log Time and Date ✓ ✓ Log 2 EVID Event Code xxxxH © Honeywell - M450 001 1D - 23.05.2019...
  • Page 66 ALCS for 5 minutes ALCS 5 ✓ ✓ State Shows ALCS State Test Long Press on SELECT Button changes State ✓ ✓ of ALCS for 5 minutes State State Change Active/Reactive or ✓ ✓ Reactive/Active © Honeywell - M450 001 1D - 23.05.2019...
  • Page 67: Identification Data

    Firmware Code Checksum • Firmware Details MCOR (version number) • Metrological Firmware Code Checksum • Firmware Bootloader (version) • Firmware ZigBee stack (version) • ZigBee Chip • MAC Address • PCB (bar code) Identifier © Honeywell - M450 001 1D - 23.05.2019...
  • Page 68: Order Of Accounting

    AS302P Single Phase Smart Meter ____________________________________________________________________ 34.8. Order of Accounting © Honeywell - M450 001 1D - 23.05.2019...
  • Page 69: Payment Based Debt Collection

    Suspend Debt 3 Debt Payment Collect Debt Collection for the Ensuring RRC is Payment Rest of the Week Not Exceeded Update the Update the Customer Account Customer Account Record record End Debt Collection © Honeywell - M450 001 1D - 23.05.2019...
  • Page 70: Utrn Processing

    AS302P Single Phase Smart Meter ____________________________________________________________________ 34.10. UTRN Processing © Honeywell - M450 001 1D - 23.05.2019...
  • Page 71: Emergency Credit Transitions

    13. The top up credit accepted by the prepayment application is insufficient to repay all debts, including emergency credit debt (where initial EC owed = EC Limit) and take the prepaid credit above the disablement threshold. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 72 AS302P Single Phase Smart Meter ____________________________________________________________________ © Honeywell - M450 001 1D - 23.05.2019...
  • Page 73: Appendices

    Various methods of checking the accuracy of registration of the AS302P meter are available. Methods using the LED test indicator and Register advances are described below. Note: The AS302P meter does not have potential disconnect links. Where multiple meters are to be tested, a multi- secondary voltage transformer will be required.
  • Page 74 The number of LED pulses should be greater than:- Itest = Test current V = System voltage Itest x V x PF x K PF = Power factor of test load K = LED pulse value, impulses/kWh © Honeywell - M450 001 1D - 23.05.2019...
  • Page 75: Appendix B - Event/Alarm Logs

    UTRN not for this Device 0x8F64 Mandated Update Security Credentials 0x8F70 Mandated Firmware Verification Successful 0x8F72 Mandated Y (2) Mandated - Unauthorised Physical Access - Meter Cover 0x8F74 conditional Y (1) Removed group 1 © Honeywell - M450 001 1D - 23.05.2019...
  • Page 76 0x81AE Non-mandated Y (1) Error Program Execution 0x81AF Non-mandated Y (1) Error Program Storage 0x81B0 Non-mandated Y (1) Error RAM 0x81B1 Non-mandated Y (1) Error Unexpected Hardware Reset 0x81B2 Non-mandated Y (1) © Honeywell - M450 001 1D - 23.05.2019...
  • Page 77 Mandated Y (1) Threshold (voltage returns above for longer than the configurable period) RMS Voltage below Voltage Sag Threshold 0x8099 Mandated Y (1) (voltage returns above for longer than the configurable period) © Honeywell - M450 001 1D - 23.05.2019...
  • Page 78 Auxiliary Load Control switch • Alert type 1 - Payload comprises Alert Code and Timestamp only • Alert type 2 - Payload comprises Alert Code, Timestamp and Use Case specific data as defined in GBCS © Honeywell - M450 001 1D - 23.05.2019...
  • Page 79: Appendix C - Interface Commands

    Reset Max Demand Active Power (Configurable (Configurable Time) Import Value Time) Import Value Reset Meter Balance Reset Meter Balance to Zero Reset Tariff Block Counter Matrix Tariff Block Counter Matrix to Zero Restrict Data Restrict Personnel Data © Honeywell - M450 001 1D - 23.05.2019...
  • Page 80 Set Prepay or Credit Mode Set Tariff Accept New Tariff Values HAN Interface Commands Issued by AS302P Control HAN Connected Auxiliary Load Open/Close Auxiliary Load Control switch for Control Switch Specified Time © Honeywell - M450 001 1D - 23.05.2019...
  • Page 81: Appendix D - Data

    A store capable of holding the largest average value of the Active Power Export Value recorded in any 30-minute period Meter Balance The amount of money in Currency Units as determined by AS302P. Payment Debt Register Debt to be recovered as a percentage of payment when using Payment-based Debt Recovery in Prepayment Mode.
  • Page 82 Time-based Debt Recovery in Prepayment Mode. Constant Data SMETS2 reference Description A globally unique identifier used to identify an individual AS302P based on the AS302P Identifier EUI-64 Institute of Electrical and Electronic Engineers standard. Manufacturer Identifier An identifier used to identify the manufacturer of the meter...
  • Page 83 Standing Charge Mode and Prepayment Mode. Supplier Message Message issued to, and held on, AS302P for provision to the Consumer Setting to control the state of the Supply in the case of Unauthorised Physical Supply Tamper State Access being detected, being Locked or unchanged.
  • Page 84: Glossary

    A Tariff Register for recording Consumption for the purposes of combined Time-of-use and Block Pricing. Block Tariff A Tariff for Block Pricing. Certificate An electronic document that binds an identity, and possibly other information, to a Public Key. Certificate Signing Request © Honeywell - M450 001 1D - 23.05.2019...
  • Page 85 An algorithm for performing one or more cryptographic functions which may include: Encryption, Decryption, Digital Signing or Hashing of information, data, or messages; or exchange of Security Credentials. Currency Units The units of monetary value in major and minor units. Customer Identification Number © Honeywell - M450 001 1D - 23.05.2019...
  • Page 86 Digital Signing The creation of a Digital Signature. Disable The act of interrupting the flow of electricity by opening the Load Switch(s) and like terms shall be construed accordingly. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 87 A component of GSME, ESME, IHD or other Device that is capable of sending and receiving information to and from other Devices. Data used to determine the output of a cryptographic operation. ICHI Intimate Communications Hub Interface © Honeywell - M450 001 1D - 23.05.2019...
  • Page 88 Personnel Identification Number PPMID Technical Specifications The document brought into force by the Secretary of State to describe the minimum capabilities of equipment installed to satisfy the PPMID licence conditions. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 89 The entitlement of a party to execute one or more Commands. Season Profile Rules defined in a Switching Table specifying a Week Profile for each week of a season. SECAS The Smart Energy Code Administrator and Secretariat. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 90 A means of recovering debt based on an amount in Currency Units per unit time. Time-of-use Band A contiguous or non-contiguous number of Days for GSME or half-hour periods for ESME over which Tariff Prices are constant. © Honeywell - M450 001 1D - 23.05.2019...
  • Page 91 Rules defined in the Switching Table specifying the Day Profile for each day of a week. ZigBee Smart Energy Profile (SEP) Version 1.2 The ZigBee Smart Energy Profile Specification 1.2a v1.0 (reference 07-5356r19: © Honeywell - M450 001 1D - 23.05.2019...
  • Page 92 These products have been manufactured with current technology and in accordance with applicable Standards Honeywell Smart Energy Elster is a registered trade mark Elster Metering Limited of Honeywell International Inc. Tollgate Business Park © 2019 Honeywell International Paton Drive, Beaconside, Stafford Inc.

Table of Contents