Sign In
Upload
Manuals
Brands
Honeywell Manuals
Measuring Instruments
GasLab Q2
Honeywell GasLab Q2 Manuals
Manuals and User Guides for Honeywell GasLab Q2. We have
2
Honeywell GasLab Q2 manuals available for free PDF download: Manual
Honeywell GasLab Q2 Manual (315 pages)
Gas Quality Analyzer
Brand:
Honeywell
| Category:
Measuring Instruments
| Size: 14.34 MB
Table of Contents
Table of Contents
3
About this Document
8
Aim / Scope
8
Important Notes to this Document
9
Abbreviations
12
Safety Information (EN-US-FRA)
16
Intended Use
18
Specific Condition of Use
20
Place of Use Environmental Conditions and Installation
21
Required Knowledge of the Personnel
23
Information and Warnings on the Device
25
Safety Information about Gases and Pressures
27
Handling Explosion-Protection Devices
29
Electrical Safety Information
33
Disconnecting Device and Cables
35
Conduit Systems and Cable Glands
37
Data Safety Information
39
Security Considerations for Your Network
39
Enforce a Strong Password Policy
39
Preventing Unauthorized External Access
40
Security for Data at Rest and Data in Transit
42
Structure and Inscriptions of Gaslab Q2
44
Connection Section
45
Instrumentation Section
47
Human-Machine Interface (HMI)
49
Type Labels and Setting Marks
50
Measuring Method and Measuring Point
55
Description of the Measuring Method
55
Measuring Point Overview
57
Gaslab Q2 after Delivery and at the Place of Use
58
Storing Gaslab Q2
59
Transporting Gaslab Q2
60
Mechanical Installation Gaslab Q2
61
Place of Use and Installation
62
Device Dimensions
64
Fluidic Installation of the Measuring Device
65
Fluid Interfaces
66
Connect the Vent Gas Line
67
Connect the Process Gas Line
69
Connect/Replace Calibration-, Verification- Gas Cylinders
70
Opening and Closing Gaslab Q2
70
Opening Gaslab Q2
70
Closing the Housing of Gaslab Q2
72
Securing the Detachable Parts for Opening the Housing
73
Electrical Installation
74
Power Supply and Electric Protection
75
Cables (Power Supply / Communication)
76
Grounding and Potential Equalisation
77
Cable Glands (Adapter / Dummy Plugs)
78
Electrical Connection Diagram and Electrical Interfaces (Inputs and Outputs)
81
Connection to Other Devices and System Parts
83
Electrical Device Test to Verify Correct Installation
91
Commissioning and Decommissioning
92
Commissioning Preparations and Requirements
93
Set Date and Time
93
Set Password for Administrator (Admin1) and Generate a New TLS Certificate
94
Adapting the Factory Parameterization
95
The Hardware Parameter Guard (SSW)
96
Additional Conditions for Fiscal Metering
98
Standard Commissioning and Normal Operation
99
Checking the Setting and Signals
100
Decommissioning and Disposal
101
Decommissioning and Disassembly
101
Disposal
103
Gaslab Q2 Operation Panel and Operation
104
Leds on the Operation Panel
105
Screen Display on the Operation Panel
106
Superimposition Keys
107
Different Types of Device Displays
108
Navigation Options
109
The Middle of the Bottom Status Line
110
Visibility of the Displays
111
Entries and Changes Using the Operation Panel
112
Displays and Functions
115
Home Display (Overview)
115
Info Display (Overview)
118
Error List - Main Display (Accept / Quit Error Messages)
125
System Display (Overview)
127
System Display Time Service (System Time and Date)
128
System Display Users (Login, Logout, Password)
134
System Display (Logbook)
140
System Display (Audit Trail)
141
System Display I/O (Network Settings / Inputs/ Outputs)
144
Display Q2 Sensor Values
146
Display Q2 Control (Calibration/Verification/Touch)
147
Q2 Main Display (Calculation Standard)
149
Display User Archives
155
Display Modbus
157
Operation and Operating Modes of Gaslab Q2
164
Operating Mode: Analysis (Automatic Normal Operation)
164
Operating Mode: Operational Calibration (Manual)
165
Operating Mode: Verification (Special Mode)
167
Configuration and Analysis Software Ensuite
171
Ensuite Basis of Use
172
First Steps to Use Ensuite
172
Data Connection to the Measuring Device
176
Saving and Managing the Device Setting
182
Update Downgrade and Bugfix-Software
188
Changing Basic (System) Settings
190
SFB I/O (IP Address Network- and I/O-Settings)
190
System Settings
193
Time Service SFB Settings and System Time Action
194
Settings Unit Service SFB and Displays
196
User and Rights Management
201
Fiscal Parameters and Optional Using of Approval File
219
Live Data and Trending Actions in Ensuite
221
Notices about Parameterization
229
Offline Parameterization
230
Online Parameterization
233
Editing Parameterizations
234
Change Settings of the Q2 AFB
236
Setting or Changing Automatic Measurements
236
Using Ensuite Functions and Other Afbs
239
Working with Archives and Logs
239
Displaying and Reading Analysis Results
243
Working with the Modbus AFB
243
The Remote Operation Panel Actions
244
Activate / Deactivate Remote Operation Panel
244
Enabling the Local Device Functions
245
Possible Malfunctions and Troubleshooting
247
Possible Error Events
247
Disturbances During Normal Operation (Troubleshooting)
248
Correct the Gas Supply Failures
249
Pressure Alarm Analysis
250
Check Pressure Sensor (Function)
251
Correct Electrical Faults
253
Correct Communication Errors
256
Resolving a "Protocol Error" (Message)
257
Sensor Errors
258
Eliminate Start-Up Errors
259
Maintenance, Cleaning and Repair
260
Spare Parts and Repairs
260
Maintenance and Maintenance Intervals at a Glance
261
Inspection Work in Detail
263
Checking the Battery Charge
263
Info Display (Display Test)
264
Check the Tightness of the Installation
264
Check Cylinder Pressure (Visual Check)
266
Check Inlet Pressures (Visual Check)
267
Checking Flows (Optical Control)
268
Check Housing Parts (Visual Inspection)
269
Check Connections (Visual Check)
270
Check Breather(S) / Device Venting
271
Advertisement
Honeywell GasLab Q2 Manual (266 pages)
GAS QUALITY ANALYZER
Brand:
Honeywell
| Category:
Measuring Instruments
| Size: 11.9 MB
Table of Contents
Contact Data
2
Table of Contents
3
1 About this Document
8
Aim / Scope
8
How to Use this Document
9
Symbols, Abbreviations and Definitions
9
Version History Updates and File Integrity
23
2 Safety and Warning Information
24
Intended Use and Responsibilities
25
Place of Use Environmental Conditions and Installation
26
Authorized (Hardware) Personnel
27
Information and Warnings on the Device Housing
27
Safety Information about Gases and Pressures
28
Handling Explosion-Protection Devices
29
Electrical Safety Information and Emergency Stop
31
Data Security Information
34
General Guidelines Software Versions and Actuality
34
Password Guidelines and Role-Based Access Control
35
Networks and Security for Data at Rest and Data in Transit
38
Preventing Unauthorized External Access Using a Firewall
39
Logging of Device Events with Logbooks
40
Reporting Security Vulnerability to Honeywell
41
Uninstalling Programs and Data
42
3 Structure and Inscriptions of the Gaslab Q2
43
Connection Section
44
Instrumentation Section
46
Human-Machine Interface (HMI)
47
Type Labels and Setting Marks
48
Explanation of Explosion Protection Markings
50
4 Measurement Technology and Measuring Point
52
Description of the Measuring Method
52
Measuring Point Overview
54
5 Gaslab Q2 after Delivery and at the Place of Use
55
Storage
56
Mechanical Installation of Gaslab Q2
57
Place of Use and Installation
57
Device Dimensions
58
Fluid Installation of Gaslab Q2
59
Fluid Interfaces
60
Connect the Vent Gas Line
61
Connect the Process Gas Line
62
Connect the Calibration Gas
63
Electrical Installation
64
Power Supply and Protection
65
Cables (Power Supply / Communication)
66
Opening and Closing the Connection Box
67
Grounding and Potential Equalisationerdung und Potentialausgleich
68
Cable Glands (Adapter / Dummy Plugs)
69
Electrical Connection Diagram and Electrical Interfaces (Inputs and Outputs)
71
Connection to Other Devices and System Parts
73
6 Commissioning and Decommissioning
79
Commissioning Preparations and Requirements
79
Set Password for Administrator (Admin1)
80
Adapting the Factory Parameterization
80
Opening and Closing the Hardware Parameter Guard (SSW)
80
Additional Conditions for Fiscal Metering
82
Standard Commissioning and Normal Operation
83
Checking the Setting and Signals
84
Decommissioning / Dismantling / Disposal
85
7 Gaslab Q2 Displays (Operate the Device)
87
Leds above the Interactive Screen
88
The (Local / Remote) Operation Panel
89
Navigation in the Operation Panels and Displays
90
The Middle of the Bottom Status Line and the Visibility of the Displays
95
Entries and Changes Using the Operation Panel
97
Displays and Functions
99
Home (Display Overview/Device Language/Start-Up Error)
99
Info Display (Overview)
102
Info Display (Serial Number and TLS Certificate)
102
Info Display (Device Monitor)
104
Info Display (Software Status)
105
Info Display (Display Test)
107
Info Display (License Info)
107
Error List - Main Display (Accepting / Quit Error Messages)
108
System Display (Overview)
111
System Display Time Service (System Time and Date)
111
System Display Users (Login/Logout / Password)
116
System Display (Logbook)
120
System Display (Audit Trail)
122
System Display I/O (Basic Network Settings / Inputs /Outputs)
124
Display Q2 Sensor Values
126
Display Q2 Control (Calibration/Verification/Touch)
127
Q2 Main Display (Calculation Standard)
129
Display User Archives
135
Display Modbus
136
Operation and Operating Modes of Gaslab Q2
137
Operating Mode: Analysis (Automatic Normal Operation)
137
Operating Mode: Operational Calibration (Manual)
137
Operating Mode: Verification (Special Mode)
139
8 Configuration and Analysis Software Ensuite
143
The PC-Software-Concept
144
The Software Blocks (Afbs/Sfbs)
144
Installation Start and Data Connection
145
Installing Ensuite
145
Starting Ensuite; the First Steps
146
General Connection Options to the Encore Device
149
Establish a Connection to the Encore Device
150
Disconnecting the Device and Connection Errors
156
Read-Out Parameterization
157
Saving, and Exporting the Parameter Set
158
Viewing the Parameterization of Sfbs and Afbs
159
User Management and Login
162
User Profile Management
163
Assigning or Changing a Password Using Online Parameterization
164
Viewing Setting and Change Access Rights
165
Viewing Position of the Security Switch
166
Access Rights Dependent Restricted Editing Options (Virtual Login)
167
Changing Existing Device Settings (Parameterization)
169
Changing Device Parameters Offline (Offline Parameterization)
171
Create a New Device Parameter Set (Offline Parameterization)
175
Changing the Device Parameter Set in the Connected Device (Online Parameterization)
180
Product and Device Parameterizations
181
Changing the IP Address Basic Network and I/O Settings
182
Setting Time-Related Values and Actions in the Time Service SFB
184
Changing Units and Adjusting Display Formats in the Unit Service SFB
186
Define Basic Display and Edit Display Behavior
191
Setting or Changing Automatic Measurements
192
Fiscal Parameters and Optional Using Approval File (Select Approval)
194
Restoring the Parameter Set to Factory Settings (Importing Data)
196
Changing the Software Configuration (Update / Downgrade)
197
Convert Original Parameterization (Optional))
204
Special Case: Bugfix Software
206
Remote Operation Panel Functions of Ensuite
207
Open and Close Remote Operation Panel
207
Enabling the Local Device Functions
208
Using Ensuite Functions in Device Operation
210
Update Date and Time (System Time Action)
210
Displaying and Reading Analysis Results
212
Working with the Modbus AFB
212
Working with Archives and Logs
213
Live Data and Trending Function in Ensuite
216
Use "Live Data Tab" as Device Monitor
219
Use "Live Data Tab" to View Time Service Data
220
Use "Live Data Tab" to View the Software Status
222
9 Possible Malfunctions and Troubleshooting
224
Disturbances During Normal Operation (Troubleshooting)
224
List of Possible Errors
228
10 Maintenance, Cleaning and Repair
232
Maintenance
232
Maintenance and Maintenance Intervals at a Glance
232
First Inspection
234
Checking the Battery Charge
235
Checking the Housing Parts
235
Checking the Breather Element/Venting System
236
Visual Inspection of the Connections
236
Checking the Interior
236
Visual Inspection of the Cylinder Pressure/Inlet Pressures
237
Flow Rate Check
237
System Tightness Test
238
Completing a Service Calibration
239
Connecting and Replacing Gas Cylinders
242
Repair Work and Honeywell Service Work
245
Device Cleaning and Documentation of the Work
246
11 Technical Data and Information
248
Explosion Protection Data
248
Reported Values and Analytical Performance
248
List of Suitable Gases and Calibration Gases
249
Notes on Device Characteristics and Operating Conditions
250
Declaration of Conformity
251
12 Keywords and Figures
252
Keyword Index
252
List of Figures
260
Advertisement
Related Products
Honeywell QA 16 DN 25 G I
Honeywell QA 65 DN 50 Z
Honeywell QA 100 DN 80 Z
Honeywell QA 160 DN 80 Z
Honeywell QA 250 DN 100 Z
Honeywell QA 400 DN 100 Z
Honeywell QAe 16 DN 25 G I
Honeywell QAe 25 DN 25 G I
Honeywell QAe 65 DN 50 Z
Honeywell QAe 400 DN 100 Z
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL