Table 7-7: Troubleshooting procedures for SMD1B/SMS4 cards

No. Symptoms
1
Green ACT indicator off Defective indicator
2
Red FAIL indicator on
or not turning off after
power-on and reset

Table 7-8: General troubleshooting procedures for extended cards PE1_63/P345_3E/

SM_10E/EM_10E/S1_4/P345_3E/DMCE1_32
No. Symptoms
1
Both red FAIL indicator
and red Alarm
indicator do not turn
off after power-on
2
Green ACT indicator
off
ECI Telecom Ltd. Proprietary
Probable cause
FPGA in module
downloaded
unsuccessfully
Defective module
Damaged software or
defective card/module
Probable cause
Boot damaged
Defective indicator
Corrective actions
Select Maintenance > LED Test in the LCT-APT
menu and check that the
indicator blinks for some time. If not, replace
the module.
Power off and wait a few minutes before
powering on again.
If the Green ACT indicator is still off,
download and activate the NE embedded
software package either through the
LCT-APT or the Boot Configuration Tool.
After the new embedded software package
is activated, the ACT indicator should be on
and the FAIL indicator should be off.
If the ACT indicator is still off, replace the
module.
If the ACT indicator is still off, replace the
NPT-1020 unit.
Perform a warm reset on the NPT-1020 by
pushing the RST button.
If the FAIL indicator is on after reset,
download and activate the NE embedded
software package either through the
LCT-APT or the Boot Configuration Tool.
After the software is completely
downloaded to the NPT-1020, the ACT
indicator should be on and the FAIL
indicator should be off.
If the FAIL indicator turns on again, replace
the module.
Corrective actions
Extract the card and reinsert it into the
extended slot on the EXT-2U. If this does not
resolve the problem, replace the module.
Select Maintenance > LED Test in the LCT-APT
menu and check that the indicator blinks for
some time. If not, replace the module.