NPT-1020 Installation and Maintenance Manual

5.18.1 Connecting Power Cables

The power cables are connected to the corresponding connectors on the NPT-1020 platform.
N
OTE: To facilitate power cable routing, it is recommended to start from the NPT-1020
platform towards the power source.
To connect a power cable:
1.
Connect the connector at the end of the power cable to the power connector of the NPT-1020 and
fasten it with its two screws.
2.
Grasp the connector at the other end of the power cable and thread it through the space between
the platform and the frame.
3.
Repeat Steps 1 and 2 for the second power cable to be connected to the corresponding connector on
the platform.
4.
Bend the cables and route them adjacent to the left side cable supports. Pull the cables until the cable
connectors are positioned against the appropriate connectors on the power source. See the following
figure for reference.
5.
Use cable ties as required to fasten the cables to the cable supports.
6.
Connect the free ends of the power cables in accordance with the frame installation plan and the
cable tags to the DC power connectors on the power source.
ECI Telecom Ltd. Proprietary

Figure 5-31: Wall-mounted frame cable routing - left side view

NPT-1020 Wall-Mounted Installations
5-39