5.7.6

Other Settings

(1) Display contrast (graduations) setting
The contrast of the display can be changed to 11 levels (+5 to -5).
The setting can be configured with the following parameter.
Menu path
Display
F
OUNDATION
Fieldbus
Block
Relative
Name
Index
LTB
26
+5
+4
+3
+2
High
NOTE
How the contrast of the display looks changes a little depending on ambient temperature.
Set the contrast of the display by taking into account the ambient temperature of the environment
where the display is used.
(2) Display damping time constant setting
This function can specify the damping time constant for the display independently of that
specified in Subsection 5.1.6.
The setting can be configured with the following parameters.
Menu path
Display
F
OUNDATION
Fieldbus
Block
Relative
Name
Index
LTB
32
NOTE
The damping time constant of the display is effective only for the display. Refer to Subsection
5.1.6. to specify the damping time constant for the output of the physical quantity.
NOTE
The damping time constant of the display is not applied to the following display item.
AI1 Flow rate, AI1 Flow rate(%), AI1 Flow rate(%Bar), AI1.OUT, AI2.OUT, AI3.OUT, AI4.OUT, IT1.
OUT, IT2.OUT, AR.OUT
For details about the display item, refer to Subsection 5.7.2.
Device setup ► Detailed setup ► Display set ► Optional config ► (see below)
Device Configuration ► LTB ► Device Configuration ► Configuration ► Display Operation
Configuration ► (see below)
Parameter
Display
Contrast
Display Contrast
+1
0
-1
-2
-3
-4
Device setup ► Detailed setup ► Display set ► Optional config ► (see below)
Device Configuration ► LTB ► Device Configuration ► Configuration ► Display Operation
Configuration ► (see below)
Parameter
Display
Damp
Display Damping
<5. Functions>
F
Fieldbus
OUNDATION
-5
Low
F
Fieldbus
OUNDATION
119
Description
Specifies the contrast of the
display.
Description
Specifies the damping time
constant of the display.
IM 01E21A02-03EN