YOKOGAWA Admag TI Series User Manual page 92

Foundation fieldbus communication type
Hide thumbs Also See for Admag TI Series:
Table of Contents

Advertisement

Error Message
NE
107
Display
F
017:AD 2 FAIL[Excit]
F
018:Coil open
F
019:Coil short
F
020:Exciter FAIL
F
027:Restore FAIL
F
028:Ind bd FAIL
F
029:Ind bd EEP FAIL
F
030:LCD drv FAIL
F
031:Ind bd mismatch
F
032:Ind comm ERR
F
033:microSD FAIL
F
244:Amp EEP FAIL
C
249:SoftDL Incmplt
C
250:SoftDL FAIL
F
251:Abnml Boot PRS
F
335:IT1 ttl bkup ERR
F
339:IT2 ttl bkup ERR
Error Description
F
OUNDATION
Fieldbus
Failure of A/D
A/D2 failure[Exciter]
transmitter 2 (exciting
current) was detected.
Coil of sensor was
Coil open
disconnected.
Coil of sensor was
Coil short
shorted.
Failure of the excitation
Exciter failure
circuit was detected.
Parameter restore
Restore of parameters
incomplete
was failed.
Indicator board
Failure of display
failure
board was detected.
Failure of EEPROM
Indicator board
(display board) was
EEPROM failure
detected.
Failure of display driver
LCD driver failure
was detected.
Indicator board
Mismatch of display
mismatch
board was detected.
Communication error
Indicator
of display board was
communication error
detected.
Failure of the microSD
microSD failure
card was detected.
Amp EEPROM
Failure of amplifier
Failure
EEPROM.
Software download
SoftDL Incomplete
incomplete.
Software download
SoftDL Failure
failed.
Abnormal Boot
Failure occurs while
Process
starting up the device.
IT1 totalized value
IT1 Total Backup Err
saving error occurred.
IT2 totalized value
IT2 Total Backup Err
saving error occurred.
<5. Functions>
Countermeasure
Contact Yokogawa
service center.
Turn off the power,
check coil of sensor
and excitation cable.
Contact Yokogawa
service center.
Contact Yokogawa
service center.
Retry parameter
restoration.
Check that the ambient
temperature of display
is within the range.
If the situation does
not improve, contact
Yokogawa service
center.
Turn on the power
again within the range
of the temperature
specifications. If the
situation does not
improve, contact
Yokogawa service
center.
Contact Yokogawa
service center.
Contact Yokogawa
service center.
Check the connection
of the display and main
board.
Change the microSD
card.
Replacement of
amplifier or device
Check cable and
power.
Check cable and
power.
Check cable and
power.
Contact Yokogawa's
sales office or service
center.
Contact Yokogawa's
sales office or service
center.
IM 01E21A02-03EN
91
FD bit
2
20
2
19
2
18
2
17
2
7
2
6
2
5
2
4
2
3
2
2
2
1
1
19
1
24
1
25
1
26
6
8
6
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Admag ti axgAdmag ti axw

Table of Contents