Display Item Setting - YOKOGAWA Admag TI Series User Manual

Foundation fieldbus communication type
Hide thumbs Also See for Admag TI Series:
Table of Contents

Advertisement

5.7.2

Display Item Setting

This product can show up to eight items on the display by scrolling it. Set each display item to the
eight display line.
The setting can be configured with the following parameters.
Menu path
Display
F
OUNDATION
Fieldbus
Block
Relative
Name
Index
LTB
14
LTB
15
LTB
16
LTB
17
LTB
18
LTB
19
LTB
20
LTB
21
From the table below, select the items to be shown on the display.
Selection
Display
None
Flow rate(%)
PV
Velocity
Volume flow
Mass flow
Flow rate(%Bar)
Calorie
Totalizer 1
Totalizer 2
PD tag
Commun protocol
Adhesion
Flow noise level
Totalizer 1 count
Totalizer 2 count
AI1 Flow rate
AI1 Flow rate(%)
AI1 Flow rate(%Bar) AI1 Flow rate(%Bar) Displays FIELD_VAL of AI1FB in a bar graph.
AI1.OUT
AI2.OUT
AI3.OUT
AI4.OUT
Device setup ► Detailed setup ► Display set ► Line select ► (see below)
Device Configuration ► LTB ► Device Configuration ► Configuration ► Line Select ►
(see below)
Parameter
Display
Line 1
Display Line Select 1
Line 2
Display Line Select 2
Line 3
Display Line Select 3
Line 4
Display Line Select 4
Line 5
Display Line Select 5
Line 6
Display Line Select 6
Line 7
Display Line Select 7
Line 8
Display Line Select 8
F
OUNDATION
Fieldbus
None
Does not display items (item 1 is not selectable).
Displays the flow rate for the span of the process value PV-mapped
Flow rate(%)
in Subsection 5.1.2.
PV
Displays the PV-mapped process value in Subsection 5.1.2.
Velocity
Displays the flow velocity.
Volume flow
Displays the volumetric flow rate.
Mass flow
Displays the mass flow rate.
Displays the flow rate for the span of the process value PV-mapped
Flow rate(%Bar)
in Subsection 5.1.2 by using a bar graph.
Calorie
Displays the calorie (only available for AXG, not for AXW).
Totalizer1
Displays the totalized value of totalizer 1.
Totalizer2
Displays the totalized value of totalizer 2.
PD Tag
Displays PD Tag.
Commun Protocol
Displays the communication protocol.
Displays the adhesion level of the electrode adhesion detecting
Adhesion
function.
flow noise level
Displays the flow noise level (only available for AXG, not for AXW).
Totalizer 1 count
Displays the count value of totalizer 1.
Totalizer 2 count
Displays the count value of totalizer 2.
AI1 Flow rate
Displays Simulate Value of AI1FB.
AI1 Flow rate(%)
Displays FIELD_VAL of AI1FB.
AI1.OUT
Displays OUT of AI1FB.
AI2.OUT
Displays OUT of AI2FB.
AI3.OUT
Displays OUT of AI3FB.
AI4.OUT
Displays OUT of AI4FB.
<5. Functions>
F
Fieldbus
OUNDATION
Description
Description
Specifies item 1 to be shown on
the display.
Specifies item 2 to be shown on
the display.
Specifies item 3 to be shown on
the display.
Specifies item 4 to be shown on
the display.
Specifies item 5 to be shown on
the display.
Specifies item 6 to be shown on
the display.
Specifies item 7 to be shown on
the display.
Specifies item 8 to be shown on
the display.
IM 01E21A02-03EN