YOKOGAWA Admag TI Series User Manual page 182

Foundation fieldbus communication type
Hide thumbs Also See for Admag TI Series:
Table of Contents

Advertisement

Relative
Index
Parameter Name
Index
LIMIT_STS_
113
2113
VEL2_VALUE
LIMIT_STS_
114
2114
VEL2_SETPOINT
LIMIT_STS_
115
2115
VEL2_ACT_
DIRECTION
LIMIT_
116
2116
STS_VEL2_
HYSTERESIS
LIMIT_STS_
117
2117
VEL2_UNIT
LIMIT_STS_
118
2118
VOL1_VALUE
LIMIT_STS_
119
2119
VOL1_SETPOINT
LIMIT_STS_
120
2120
VOL1_ACT_
DIRECTION
LIMIT_STS_
121
2121
VOL1_
HYSTERESIS
LIMIT_STS_
122
2122
VOL1_UNIT
LIMIT_STS_
123
2123
VOL2_VALUE
LIMIT_STS_
124
2124
VOL2_SETPOINT
LIMIT_STS_
125
2125
VOL2_ACT_
DIRECTION
LIMIT_STS_
126
2126
VOL2_
HYSTERESIS
LIMIT_STS_
127
2127
VOL2_UNIT
LIMIT_STS_
128
2128
MASS1_VALUE
LIMIT_STS_
129
2129
MASS1_
SETPOINT
LIMIT_STS_
130
2130
MASS1_ACT_
DIRECTION
LIMIT_STS_
131
2131
MASS1_
HYSTERESIS
LIMIT_STS_
132
2132
MASS1_UNIT
LIMIT_STS_
133
2133
MASS2_VALUE
LIMIT_STS_
134
2134
MASS2_
SETPOINT
LIMIT_STS_
135
2135
MASS2_ACT_
DIRECTION
LIMIT_STS_
136
2136
MASS2_
HYSTERESIS
LIMIT_STS_
137
2137
MASS2_UNIT
Write
Default Value
Mode
0x1C
-
0
-
-10
O/S
0(Low limit)
O/S
0
O/S
1061(m/s)
-
0x1C
-
0
-
282.7433
O/S
1(High limit)
O/S
0
O/S
1349(m
/h)
-
3
0x1C
-
0
-
-282.7433
O/S
0(Low limit)
O/S
0
O/S
1349(m
/h)
-
3
0x1C
-
0
-
1
O/S
1(High limit)
O/S
0
O/S
1324(kg/h)
-
0x1C
-
0
-
-1
O/S
0(Low limit)
O/S
0
O/S
1324(kg/h)
-
<6. Parameter Lists>
Description
See 5.3.1 ■ Flow velocity limit
switch.
See 5.3.1 ■ Flow velocity limit
switch.
See 5.3.1 ■ Flow velocity limit
switch.
See 5.3.1 ■ Flow velocity limit
switch.
See 5.3.1 ■ Flow velocity limit
switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Volumetric flow rate
limit switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
See 5.3.1 ■ Mass flow rate limit
switch.
181
IM 01E21A02-03EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Admag ti axgAdmag ti axw

Table of Contents